4 Lock functions
The lock should only be programmed with the lock and safe opened.
The works primary code is 1 2 3 4 5 6. No secondary code is set by works.
4.1 Opening with primary or secondary code
1) Press ON
2) Enter valid 6-digit primary or secondary code
3) Within 4 seconds turn bar handle clockwise until stop position reached
If the lock was last opened with a different code, the signal 3 x
4.2 Opening after 3 or more incorrect code entries  penalty time
After 3 incorrect entries the lock goes into a one minute blocked status. The period in which
the lock is blocked is extended to 2, 4, 8 and a maximum of 16 minutes every time an incorrect
code is entered. During this period the red LED flashes every second and it is not possible to
enter any further codes. When the blocked period is over, ON may be pressed again at any
time.
1) Press ON
2) Enter valid 6-digit code
Signal: Invalid 6-digit code was entered during former opening attempt
3) Within 4 seconds turn bar handle clockwise until stop position reached
Kaba Mauer GmbH
primary code
secondary
82021 Code-Combi K
code
appears.
GB
1 x
1 x
3 x