2.2 Hysteresis-MODE:
During the course of the set point setting either the switch-on flank (n.o status) or the switch-off flank (n.c status) will
blink, depending on the operating mode. When setting the hysteresis mode consequently the hysteresis mode will
blink. Depending on the set polarity (n.c. / n.o. see setup) the hysteresis diagram will appear on the display with the
Picture 2: Switching OUT 1n.o., switching OUT 2 n.c.
2.3 Window MODE:
This operating mode provides the definition of a switching point and a reset point within a pressure range. In case the
prevailing pressure is within this "window", the switching out will be activated (polarity n.o.) or inactivated (polarity
n.c.)
Picture 3: Switching OUT 1 n.o., switching OUT n.c.

3. Error- and warning messages:

LO VOLT
Supply voltage too low
HI PRES
Pressure signal too high or sensor defekt
LO PRES
Sensor defect
HI TEMP
Temp. Signal too high or sensor defect
4. Despatch settings
– Display bar
– Switching mode Standard n. o.
– Switch on/off delay 0 sec.
Electrical connection M 12 x 1
Pin
Signal
1
+ U
B
2
Out 2 (PNP) / analog 4 to 20 mA white
3
0 Volt
4
Out 1 (PNP)
5
PE
adjustable switching flank blinking.
LO TEMP
CALI
ESET
ESH1 (2)
Your settings
Function keys and display
Cable
LED Output 2 (optional)
brown
blue
Indication for Operating MODE
black
7-segment display (4 digits)
grey
Dot-Matrix for additional informations
Indication during adjusting setpoint and
Keypad with 3 buttons
9
Temp. Signal too low or sensor defect
Pressure switch not properly calibrated
Pressure switch not properly
calibrated
SETUP settings OUT 1 (2)
for mode, on/off time not correct
LED Output 1
OUT1 HYS WIN OUT2
resetpoint
SET
7503442.99.10.01

Werbung