Range
The transmission range of the radio signals, between the handheld radio transmitter and the
radio-controlled switch socket, is up to 30 m under optimum conditions.
This value, however, is the so-called "open space range" (the range when the transmitter and
receiver are visible to each other, without disturbing influences).
In practical operation, however, there are walls, ceilings of rooms, etc. between the transmitter
and the receiver, which reduce the range accordingly.
Due to the different influences on the wireless transmission, no specific range can be guar-
anteed.
However, trouble-free operation is usually possible in a single family house.
Sometimes the range can be considerably reduced due to:
• Walls, reinforced concrete ceilings
• Coated/metallised insulated glass
• Proximity to metallic & conductive objects (e.g., heating elements)
• Proximity to human bodies
• Broadband interferences, e.g., in residential areas (devices using the same transmission
frequency, radio controlled headphones, radio controlled speakers, radio controlled weather
stations, baby monitoring systems, etc.)
• Proximity to electric motors, transformers, power-supply units, computers
• Proximity to badly shielded or uncovered computers in use or other electrical appliances
Disposal
a) Product
Electronic devices are recyclable material and do not belong in the household waste.
Dispose of product at the end of its life cycle in accordance with the applicable
statutory regulations.
Remove any inserted battery and dispose of it separately from the product.
b) Batteries/Rechargeable Batteries
As the end user, you are required, by law, (Battery Ordinance) to return all spent batteries/
rechargeable batteries; disposal of them in the household waste is prohibited.
Batteries/rechargeable batteries contain harmful materials and are labelled with the
symbol shown to indicate that disposal in the household waste is forbidden. The
symbols of the critical heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead (the
marking can be seen on the battery/rechargeable battery, e.g., underneath the re-
fuse bin symbol shown on the left).
You can return your used batteries/rechargeable batteries free of charge at the official col-
lection points of your community, in our stores, or at places where batteries or rechargeable
batteries are sold.
That way you are fulfilling your statutory obligations and you are contributing to the protection
of the environment.

Declaration of Conformity (DOC)

We, Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this
product conforms to the 2014/53/EU directive.
The full text of the EU conformity declaration is available via the following Internet
address:
www.conrad.com/downloads
Select a language by clicking a flag symbol and enter the order number of the prod-
uct in the search field; then you will be able to download the EU declaration of
conformity in PDF format.
Technical Data
a) Radio controlled handheld transmitter
Power supply .................................... 1x 12 V battery, type "23A"
Transmission frequency.................... 433.92 MHz
Transmission power.......................... <10 dBm
Range ............................................... up to 30 m (open space, see chapter "Range")
Address codes .................................. 4 (adjusted with sliding switch "I, II, III, IV" to operate
multiple identical systems independently of each other)
Switching channels ........................... 4 (each with "ON"/"OFF"-button)
LED ................................................... lights up briefly, when the buttons are used
Operating environment ..................... Only suitable for enclosed, dry indoor locations
Ambient conditions ........................... Temperature 0 °C to +45 °C, air humidity <90% relative,
non-condensing
Dimensions ....................................... 40 x 110 x 16 mm (W x L x H)
Weight .............................................. 32 g (without battery)
b) Radio controlled switch socket
Operating voltage ......................... 230 V/AC, 50 Hz
Protection type .............................. IP44
Protection class ............................ I
Power rating ................................. Ohm resistive load max. 2000 W (230 V/AC, 8.7 A)
Inductive load max. 300 W (230 V/AC, 1.3 A)
Devices with mainly resistive load are, e.g., light bulbs, heaters, etc.
Powered devices with inductive load are, e.g., engines, control gears, conventional
transformers, energy-saving bulbs, etc.
Switch type ................................... Relay (single-pole)
Reception frequency ..................... 433.92 MHz
Address codes .............................. 4 (to be set via coding switch I, II, III, IV)
Switching channel ......................... Adjustable with coding switch "1 2 3 4"
Socket with child protection .......... yes
Operating environment ................ Indoor/outdoor areas (ensure correct positioning for opera-
tion in the outdoor area; see chapter "Start-up"!)
Operating conditions ..................... Temperature -20 °C to +45 °C
Dimensions ................................... 61 x 115 x 86 mm (W x H x D, including plug)
Weight .......................................... 143 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
© Copyright 2018 by Conrad Electronic SE.
1555327_V4_0318_02_VTP_m_en

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis