An example for programming zone 4 with maximum sensitivity: after press-
ing the keys twice at the same time at the start of programming, press 1, 1
again then 0 in turn and finally press both keys again at the end of pro-
gramming.
2
Testing the chosen zone (fig. E)
Press and hold down the detector's test key for roughly 7 seconds until the
test indicator light goes out. It will then flash 1 to 4 times according to the
programmed zone. For example, the test indicator light will flash 3 times if
zone 3 is program-med. If the detector does not react as you expect,
reprogramme the chosen zone.
You have assigned your detector its chosen zone. If you wish to change
this zone at any stage you must programme the zone and sensitivity pro-
gramming operation.
FIG. F, G
H
and
Fixing
For reasons of security and long battery life of the detector, the ins-
tallation of the anti-tamper pin is obligatory. In case of omission or of
incorrect installation of the pin, the red LED flashes continuously
when the detector is fitted to its bracket or to the wall.
I To fix on an adjustment axis (fig. F)
G
Hold the back plate
on the wall in the desired position to mark where
to drill the holes.
G
Drill the wall.
G
Insert the long screw
into the back plate and fasten the back plate to
the wall.
G
Put the back plate cover
Insert the adjustment axis
G
G
Position the base of the movement detector (a figure shows the top of
the base).
G
Tighten the securing screw
the movement detector can be adjusted.
G
Detach pin n° 3 from the selection supplied
G
Place the anti tamper pin in position.
G
Place the movement detector on the base and turn it to approximately
the right angle.
I To fix in a corner (fig. G)
G
Select the pre-drilled holes in the base of the movement detector for cor-
ner fixing.
G
Hold the back plate on the wall in the desired position to mark where to
drill the holes (a figure indicates the top of the base).
G
Drill the wall and fix the base.
G
Detach pin n° 2 from the selection supplied
G
Place the anti tamper pin in position.
G
Place the movement detector on the base.
I To fix flat (fig. H)
G
Select the pre-drilled holes in the base of the movement detector for
fixing flat.
18
in place.
into the long screw.
, but not too much, so that the direction of
.
.
G
Hold the back plate on the wall in the desired position to mark where to
drill the holes (a figure indicates the top of the base).
G
Drill the wall and fix the base.
G
Detach pin n° 1 from the selection supplied
G
Place the anti tamper pin in position.
G
Position the movement detector on the base.
FIG. I
Test
Representation of the range and area protected.
Press the test button on the detector to put it into the test mode. The red
light indicator comes on while you press, a test period of 1 minute 30 sec-
onds is starting.
Pass in front of the detector once or several times: the red light indicator
comes on to indicate each detection.
About fixing on an adjustment axis (fig. F), if the orientation of the detector
is not ideal, you can improve it thanks to the multi-directional ball and soc-
ket joint. When the orientation is decided, open the detector casing and
block the ball and socket joint without forcing.
If the sirens sound, send an off order using the keypad or a remote control.
After the test period, the detector returns to the normal operating
mode and the light does not come on upon motion detection. The
detector only sends radio signals to the control panel every 1 minute
30 seconds at most.
Carry out a genuine test of the detector using the alarm system (see
Logisty installation guide chapter 6).

Warranty

The warranty conditions of the motion detector are the same as those
given in the documents supplied with the control panel.