OPERATING & CHANGING THE VAPING MODES
Setting the CCT Mode (Customized Curve of Temperature)
In the relevant VT mode, press the Mode button three times in a row to return the submenu. After pres-
sing the Mode button again, you can use the "Plus" and "Minus" buttons to trigger "3) CCT" and select
it with the Mode button. Press the Plus or Minus button to set the temperature. Press the Fire button to
set the preheat time. When all modifications are finished, press the Mode button to save and exit.
Setting the Bypass Mode
The output voltage is set and regulated in the bypass mode. The higher the charge of the battery, the
more the output voltage decreases. In this mode, the device can supply coils with a resistance in the
range of 0.05 Ohm to 5 Ohm.
Select Bypass mode by pressing the Mode button three times consecutively and then selecting Bypass
mode in the main menu using the Plus or Minus button. Press the Mode button one more time to
confirm that you have selected this mode.