Mini Identifier R-1234yf
5

Technical description

The analytical device uses infrared radiation to measure the concentration of
hydrocarbon and air in refrigerant R-1234yf. In addition, the analytical device
checks whether there is too much air in the cooling system.
A manual pump cleans refrigerant residue from the device and calibrates it.
Seven LEDs indicate the measurements:
5.1

Display and control elements

No. in
fig. 2,
Description
page 2
1
LED "Pass"
2
LED "Fail"
3
The "Next" button
4
Connecting bushing for
connection cable
5
LED "Excess Air"
6
LED "Fault"
7
LED "Analysing"
8
LED "Calibrating"
9
LED "Warm up"
EN
Technical description
Explanation
Refrigerant has a purity of
Refrigerant has a purity of < 95 %
Calls up the next step in the
measuring routine
There is too much air in the
cooling system
Measuring failed
Device is analysing the refrigerant
Device is calibrating
Device is warming up
≥ 9
5 %
15