Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB

6. Operation

Press the On/Off button 1 ON. The device always starts in cross-line mode
with levelling monitoring. After switching the device on, it immediately emits
a laser beam from outlet 3.
MEASUREMENT FUNCTIONS
Operation with levelling monitoring
With the levelling monitoring option, the device automatically compensates
uneveness within the self-levelling range of approx. 5°. The levelling process
is completed as soon as the laser line stops moving. If automatic levelling is
not possible, e.g. because the device's base deviates from the horizontal
plane by more 5°, a warning signal is emitted and the laser shuts down.
In this case, set up the device in a horizontal position and wait for the
self-levelling operation.
Cross-line mode (see illustration)
Place the device on a firm horizontal surface or fasten it to a tripod and switch
it on. The laser is in cross-line mode with levelling monitoring and it
generates a horizontal line and a vertical line.
Horizontal mode (see illustration)
Press the mode
button once. The laser is in horizontal mode with levelling
monitoring and it only generates a horizontal line.
Vertical mode (see illustration)
Press the mode
button again or press it twice after switching on the
device. The laser is in vertical mode with levelling monitoring and it only
generates a vertical line.
19

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Hultafors XL2

Inhaltsverzeichnis