6. Alarm Set Mode
Press SET button will enter the alarm set mode when the meter is
already in data hold mode, the "RISK"-Icon appears on the LCD,
You can use the UP and DOWN button to adjust the threshold.
Press the "SET" button shall save the alarm setting. Then "WET"
icon appears on the LCD, you can use the UP and DOWN button
to adjust the threshold. Press the SET button shall save the alarm
setting and then the meter back to the data hold Mode, if the
moisture measurement is higher than the RISK alarm setting. It
shall beep once every 2 sec. If moisture measurement exceeded
the "WET" alarm setting, it shall beep four time every 1 sec.
Note: The RISK value is adjust 0 to 50. The default value is 30.
The WET value is adjust 50 to 100. The default value is 60.
Backlight
Press UP button to switch the backlighting on or off.