Herunterladen Diese Seite drucken

Alecto WS-1330 Bedienungsanleitung Seite 4

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

USER GUIDE
1
COM
2
COM
3
WET
COM
Thermometer with wireless outdoor sensors
WS-1330
SETUP
Several functions on the indoor unit may be adjusted. The tempera-
ture values can be displayed in ºC or ºF. For each segment you may
set a maximum and minimum values alert. When the measurement
value is above or below this set value, the alert will sound. There's an
alert function for both the temperature and the humidity.
High and low alert setup:
The same procedure applies to each segment.
1.
Use the "CH/+" button to select the desired segment (1, 2, 3
or IN).
2.
Press and hold the "ALERT" button for 3 seconds, the tempera-
ture and HI AL icon start flashing.
3.
Use the "+" and "-" buttons to input the desired high tempera-
ture alert.
4.
Press and hold the "ALERT" button for 3 seconds to activate the
alarm.
5.
Press the "ALERT" button to continue to the low temperature
alert setup. The LO AL icon starts flashing.
6.
Use the "+" and "-" buttons to input the desired low tempera-
ture alert and follow point 4 to activate.
7.
Press the "ALERT" button to continue to the high humidity
value setup. The HI AL icon starts flashing.
8.
Use the "+" and "-" buttons to input the desired high humidity
value alert and follow point 4 to activate.
9.
Press the "ALERT" button to continue to the low humidity
value setup. The LO AL icon starts flashing.
10.
Use the "+" and "-" buttons to input the desired high humidity
value alert and follow point 4 to activate.
11.
Press the "ALERT" button to leave the setup menu.
12.
Follow point 4 again to deactivate alarm points.
The above setup procedure applies to segments 1, 2, 3 and IN.
ºC or ºF display setup:
The indoor unit can display the temperature in ºC or ºF.
To change this;
1. Press and hold the "CF/-" button for four seconds.
2. The display will switch between ºC and ºF.
OVERVIEW
The display of this thermometer is divided
into 4 segments. These 4 segments are
nearly identical. 1, 2 and 3 are for the
outdoor sensors and IN is for the data of
the indoor unit. The functions of the indoor
unit are described below.
7
1
WET
1.
Function button
HI AL
HI AL
MAX
COM
2.
Temperature display
MIN
LO AL
DRY
LO AL
3.
Minimum/maximum values indication
6
2
4.
Indoor thermometer indication
WET
HI AL
HI AL
MAX
COM
5.
Outdoor sensor 3 indication
MIN
LO AL
LO AL
DRY
6.
Outdoor sensor 2 indication
5
3
7.
Outdoor sensor 1 indication
WET
HI AL
HI AL
8.
Display in ºC or ºF
MAX
COM
MIN
LO AL
LO AL
9.
Trend indication(in 1 hour 1ºC higher:
DRY
4
- next period 1ºC higher or equal:
%
RH
WET
- next period 1ºC lower or equal:
HI AL
HI AL
3
MAX
COM
MIN
- lower by 1ºC in 1 hour:
LO AL
DRY
LO AL
2
temperatuur variatie kleiner dan 1ºC:
8
10
12
14
)
9
11
13
10. High or low temperature alert indica-
tion
1
11. Humidity display emoticon (Com:
20-28ºC / 40-70%, Wet: all tempera-
tures / > 70%, Dry: all temperatures
/ <40%)
12. Humidity display
13. Values % indication
CH/+
CF/-
ALERT
14. High or low humidity alert indication
15. Channel indication (CH)
16. Temperature display
%
RH
17. Transmission indication icon
22 23 24
18. Set transmission channel display
15
17
19
21
19. Humidity display
16
18
20
20. Empty battery indication icon (in this
25 26
case, replace the batteries)
21. Display in ºC or ºF
22. "CH/+" button
23. "CF/-" button
24. "ALERT" button
25. "C/F" button
26. "CH" button
OPERATION
Maximum and minimum measured value:
Press the function button at the front. The selected segment shows
the maximum measured value with the "MAX" icon in the display
(temperature and humidity).
At this display press the function button again to display the min-
imum measured value. The "MIN" icon appears (temperature and
humidity).
Press the function button again to show the actual values (tempera-
ture and humidity).
or
1. Use the "CH/+" button to select the desired segment (1, 2, 3 or
IN).
2. Now briefly press the "CF/-" button to switch the display be-
tween the "MAX", "MIN" and "actual" values.
To delete the maximum and minimum measured values:
You may delete the maximum and minimum values for each seg-
ment separately.
1. Use the "CH/+" button to select the desired segment (1, 2, 3 or
Service
Help
IN).
2. Briefly press the "CF/-" button to select the "MAX" value.
3. Press and hold the "CF/-" button to delete the maximum values
WWW.ALECTO.NL
(temperature and humidity).
SERVICE@ALECTO.NL
4. Briefly press the "CF/-" button to select the "MIN" value.
5. Press and hold the "CF/-" button to delete the minimum values
Hesdo, Australiëlaan 1
(temperature and humidity).
5232 BB, 's-Hertogenbosch
The Netherlands
The maximum and minimum values of the selected segment are now
deleted. To delete the maximum and minimum value of all segments,
v3.0
please repeat the above for each segment (1, 2, 3 and IN).
Service
WWW.ALECTO.NL
SERVICE@ALECTO.NL
Help
Hesdo, Australiëlaan 1, 5232 BB,
The Netherlands
's-Hertogenbosch,
v3.0
INSTALLATION
Indoor unit power supply:
1. Press the tab of the battery
cover downward and pull the
cover off the indoor unit.
CH/+
CF/-
ALERT
2. Insert 2 batteries, type AAA,
1.5Volt, according to the
markings inside the battery
compartment. Batteries are
not included.
3. Replace the battery cover.
As soon as the batteries are
installed, the outdoor unit
starts searching for any nearby
outdoor sensor for 3 minutes.
-
In the display the
icon starts
flashing for each segment. Perform
instructions 4 through 6 within
3 minutes or refer to "manual
registration".
4. Slide the battery cover at the rear
of the outdoor sensor downward
and remove it.
5. Insert 2 batteries, type AAA,
1.5Volt, according to the mark-
ings inside the battery compart-
ment. Batteries are not included.
6. Set the outdoor sensor to the
desired transmission channel 1,
2 or 3 by pressing the "CH" button. The display will show which
channel you've selected. While adjusting, data is briefly transmit-
ted to the outdoor unit (see transmission indication icon
the registration. Use a unique channel for each outdoor sensor.
7. Use the "C/F" button to indicate the outdoor temperature in ºC
or ºF in the display of the outdoor sensor.
8. Replace the battery cover.
Positioning tips:
• Never place the indoor unit in direct sunlight and keep it away
from heat radiating objects (lights, heaters, etc.)
• Never place the indoor unit next to large metal surfaces or heavy
electrical equipment, ensuring proper reception of the radio
controlled signals.
• The outdoor sensors not waterproof. Always place these sensors
on a spot protected against rain and wind.
• The distance between the indoor unit and outdoor sensor should
be no more than 50 meters. The transmission range can be
affected by nearby devices transmitting on 433.92 MHz.
• The range also depends on obstacles. Concrete walls between the
outdoor sensor and indoor unit will reduce the transmission range
more than plaster walls.
Rechargeable batteries:
You can choose to use normal (alkaline) or rechargeable batteries in
both the indoor unit and the outdoor sensor. However, rechargeable
batteries provide a lower voltage, reducing the lifespan and accu-
racy of the thermometer. Rechargeable batteries must be charged
using an external charger.
BATTERY REPLACEMENT
Indoor unit:
After replacing the batteries of the indoor unit, all memories and
settings will be deleted.
Outdoor sensor:
After replacing the batteries of the outdoor sensor, you'll need to
re-register it to the indoor unit.
To do this, follow the instructions of chapter 'Installation'.
Note that the "CH" button has the desired channel set.
V1.1
Manual registration:
Starting the registration of the outdoor sensor on the indoor unit
may be done manually. Follow the instructions below to manually
register the outdoor sensors.
The display of the indoor unit must be on
CH/+
CF/-
ALERT
stand-by (no flashing icons).
1. Use the "CH/+" button to select the desired channel.
2. A dash underneath the channel number indicates which
channel is selected.
3. Now press and hold the "CH/+" button for 3 seconds until
the reception icon
starts flashing.
4. Open the battery compartment of the outdoor sensor and insert
the batteries if not already done so.
5. Press the "CH" button of the outdoor sensor until the
desired channel is selected.
6. While selecting, the outdoor sensor transmits data to the
indoor unit.
7. The indoor unit now displays the value of the outdoor
sensor in the segment with the corresponding number.
8. Use the "C/F" button to have the outdoor temperature
shown in ºC or ºF in the display of the outdoor sensor.
+
9. Replace the battery cover.
The channel that hasn't received any data is indicated by dashes.
The indoor temperature is always shown after inserting the batter-
ies.
Indoor unit and outdoor sensor placement:
The outdoor sensor may be placed onto a flat surface or suspended
from a wall by means of the suspension eyelet. Before fixing it to a
wall, first check whether the distance between the out-
door sensor and indoor unit is sufficient for the indoor
) for
unit to properly receive the signal from the outdoor
sensor.
You may use the table stand to place the indoor unit onto a flat
surface or you may use the suspension eyelet to
install the unit on a wall.
RESET/SYSTEM ERROR
If the thermometer shows a possible error, you may have to reset
the indoor unit and outdoor sensor.
1. Remove the batteries from the indoor unit and outdoor sensor.
2. Wait for at least 10 seconds and then replace the batteries.
3. Follow the registration procedure (see paragraph 'Installation').
After several seconds the indoor unit and outdoor sensor will have
recognized each other and you can start using the thermometer
again.
If you still have no connection or sound, please contact the customer
service of Alecto: www.alecto.nl
SPECIFICATIONS
Indoor unit:
indoor temperature measurement range:
0°C ~ +50°C measuring time 30 sec.
measuring range humidity inside: 20% ~ 95% measuring time 30 sec.
Power supply:
2x 1.5V battery, size AAA, alkaline
Outdoor sensor:
measuring range temperature sensor:
-40°C ~ +70°C
measuring range humidity sensor: 20% ~ 95%
Power supply:
2x 1.5V battery, size AA, alkaline
Transmitting frequency:
433.92 MHz
Maximum power:
< 0 dBm
Range:
up to 30 meters
DECLARATION OF CONFORMITY
This product is in accordance with the essential conditions and provi-
sions as stipulated in the European directive 2014/53/EU. This decla-
ration is available on: http://DOC.hesdo.com/WS-1330-DOC.pdf
CH/+
CF/-
ALERT
CH/+
CF/-
ALERT

Werbung

loading