DLC7072 / DLC7075
RS232 DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking,
ack/nack disabled, fifo enabled, delay disabled, rx timeout 5
sec.;
DATA FORMAT
code length not transmitted, no header, terminator = CR-LF,
character replacement disabled
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, num lock unchanged, delays
disabled;
DATA FORMAT
code length not transmitted, no header, terminator = ENTER,
character replacement disabled
PEN EMULATION DEFAULT SETTINGS
interpret mode, conversion to code 39 disabled, output level
normal, idle level normal, minimum output pulse 600 µs,
overflow medium
POWER SAVE
standby disabled, Illuminator off before beep, sleep disabled
READING PARAMETERS
trigger type = hardware, trigger signal = level, no timeout,
Flash On = 1 sec, Flash Off = .6 sec, one read per cycle,
safety time .5 sec, beeper intensity high, tone 2, factory
software focus range
: code identifier disabled, no field adjustment,
: code identifier disabled, no field adjustment,