Inhaltsverzeichnis
8.

Faults and remedies

Type of fault
LED display not on
smartDRAFT Tap does
not fi t on the
smartDRAFT Keg
smartDRAFT Tap is not
working
too much foam
drink is too warm
compressor does not work compressor is not switched on
cooling fi ns in the
smartDRAFT Cooler are not properly closed
covered in ice
advert display on the
unit's rear – side
does not light up
20
Possible causes
plug not connected
power supply unit defective
LED's display defective
the front part of the smartDRAFT Tap
does not lie in the cut-out in the
top ring of the smartDRAFT Keg
the smartDRAFT Tap was not attached completely withdrawn the smartDRAFT
completely withdraw
smartDRAFT Tap is not attached
properly
smartDRAFT Keg has not been
pre-cooled
dispensing temp. not yet reached
doors of smartDRAFT Cooler are
not properly closed
smartDRAFT Keg has not been
pre-cooled
cooling fan motor dirty or defective
ventilation grille is covered
unit placed too close to a wall
refrigeration circuit leaks or the
compressor is defective
or is defective
doors of smartDRAFT Cooler are
smartDRAFT Cooler has been
operated without a Keg
check that the toggle switch is
switched on
lighting defective
Remedy
put the plug in
inform service technician
attach the smartDRAFT Tap so that
the front part fi ts in the cut-out
of the top ring
Tap and attach it on the Keg
please refer to instruction on
page 9
pre-cool smartDRAFT Keg and
pay attention to LED display
and wait until the Keg has reached
8°C.
wait until LED Display has reached
8°C
close doors until you hear locking
clip click into place
pre-cool smartDRAFT Keg and,
pay attention to teh LED display.
inform service technician
uncover grille
ensure suffi cient distance
inform service technician
inform service technician
remove the plug from the power
supply, allow the fi ns to defrost.
Mop up any moisture with a soft
cloth. Always close the doors until
you hear the locking clip click
into place.
remove the plug from the power
supply, allow the fi ns to defrost.
Mop up any moisture with a soft
cloth. smartDRAFT Cooler
may only be operated with a
smartDRAFT Keg
switch on or inform the service
technician
inform service technician