Installing the heating panel
1. On the rear, first test how the brackets sit correctly in the heater. Measure
the hole distances on the brackets to determine the dimensions for fixing
the bracket to the wall.
2. Once you have determined the distance, position the brackets on the wall
and mark the wall where the holes are to be drilled.
3. Drill 4 holes in the wall. Ensure you use the correct dowel for solid walls,
cavities, plasterboard walls, etc. It will depend on the condition of your wall.
6. Use 6 x 80 mm screws to secure the bracket to the wall. We recommend
using washers so that the screws can be tightened securely.
7. Now fit the heater to the bracket.
Commissioning
1. Plug the heater into a standard socket with 230 V ~ 50 Hz A.C. voltage.
2. The thermostat on the side can be used to switch the heating on and off,
and to set the heating output to one of three levels.
2. It takes approx. 10-15 min. for the heater to reach its full effect and for
pleasant warmth to be felt.
Note:
For rooms that have cooled down completely, it can initially take a while until
the room becomes warm.
Safety:
Should the heater overheat, there is an internal safety switch that will deactivate
the hybrid heater.