10. Troubleshooting guide

Faults
Motor fails to start
- No mains voltage
up
- Pump rotor blocked -thermostat
switched off
No intake
- Non-return valve dirty
- Pump chamber without water con-
nection
- Air in intake line air-tight
- Max. suction height exceeded
Inadequate delivery
- Suction height too high
rate
- Coarse fi lter dirty
- Water level falling rapidly
- Pump performance diminishedby
contaminants part
Thermostat swit-
- Motor overloaded - friction caused
ches pump off
by foreign substances too high
Anl_GE_GP_5537_E_SPK1.indb 21
Anl_GE_GP_5537_E_SPK1.indb 21
GB
Cause
- Check voltage
- Dismantle and clean pump
- clean
- Fill water into intake
- Make sure intake line is close
- Check suction height
- Check suction height
- clean
- Place the suction hose at a deeper
level
- Clean pump and replace wearing
- Dismantle and clean pump. Prevent
intake of foreign substances (fi lter)
- 21 -
Remedy