Heating in-between seasons
Heating the stove in between seasons, when the outside
temperatures are higher, the flue gases may not be able to
escape completely and this may lead to disturbances in the
chimney draught, especially if the temperatures are rising
suddenly. The stove has to be charged with less wood and
the primary air has to be increased so that the wood can
burn down faster (with visible flames) and thus the chimney
flue can stabilize.
4. THE MOST IMPORTANT SPARES—OVERVIEW
Keramott
Description
Bottom left, Keramott
Bottom right, Keramott
Wood retainer, Keramott
Rear, Keramott
Side component left, Keramott
Side component right, Keramott
Baffle plate, Keramott
Grate
Gaskets
Description
Flat gasket 8x2 mm (1,8 m)
Gasket round Ø 6 mm (2 x 0,5 m)
Gasket round Ø 14 mm (1,8 m)
Other parts
Description
Door - cast grey
Door- nougat
Door handle
BA1 door spring
Door glass
Glass cleaner ½ litre
Stove lacquer - cast grey
Stove lacquer - nougat
Accessories
You can obtain floor plates of glass or steel, fireplace utensils, care products or the Heat Memory System for heat storage
from your certified dealer.
IMPORTANT
:
Have defective parts replaced by your certified dealer. This will guarantee that your stove functions
properly and safely.
The fireplae must not be attered.
Maintenance
To clean the glass, please use a specialised product such as Thermohit glass cleaner. Lacquered surfaces are to be
cleaned only with a cloth (may be damp). Special cleaning agents should also be used for stainless steel surfaces. Only
gaskets in good order ensure the proper function of your stove!
Cleaning
The stove, flue outlets and smoke pipes should be cleaned and inspected for deposits every year – if necessary more often,
e.g. after the cleaning of the chimney. The chimney also has to be cleaned regularly by the chimneysweeper. Your
chimneysweeper will inform you of the necessary inspection intervals. An expert should inspect the stove annually.
Part
Nr.drawing
number
1
714930
2
714931
3
714932
4
714933
5
714934
6
714935
7
714336
8
716408
Part
Nr.drawing
number
13
710096
14
710696
15
718429
Part
Nr.drawing
number
9
718883-29
9
718883-43
10
714661
11
718837
12
716801
--
640070
--
650002
--
650005
7
Chimney fire
A chimney fire may occur, due to sooting and deposits in the
chimney, if wrong or humid fuel is used. Close all air inlets
on the fireplace/chimney immediately and call the fire
brigade. Please have an expert inspect your chimney for
cracks and air-tightness after the burning out of the
chimney.
Keramott numbering = installation instructions!