save
hour
min.
extension
p.
timer
c ck
vent.
fuel
set
room
H: The TIMER indicator
light indicates that the
timer function has been
switched on.
The available temperature settings range from 6°C minimum to 28°C maximum.
When the heater has been unplugged for more than 10 minutes (or after a power
failure), the temperature will reset to the factory setting of 20°C.
F

USING THE TIMER

The timer allows you to switch on the heater automatically at a preset time.
In order to switch on the timer, the correct time must have been set (refer to
Section C) and the heater should be off.
Follow the procedure below:
Press the
button
1
The TIMER light and the information display ¹ will start blinking.
2
Use the adjustment keys
Use the key on the left ( hour) to set the hours and the key on the right
( min.) to set the minutes (interval of 5 minutes).
After approximately 10 seconds the information display will show CLOCK
3
again and the TIMER indicator light will light up, indicating that the timer
function has been activated (Fig. H).
The timer will ensure that the room will have been heated to approximately
4
the required temperature at the set time.
When you want to switch off the heater and ignite it again with the timer, all
you have to do is press the TIMER key (refer to Section G).
Press the
button
G
SWITCHING OFF THE HEATER
There are two ways to switch off the heater.
Press the
button
1
signal. Within approximately one minute the flame will have extinguished.
Press the TIMER key
2
again with the timer the next time. This not only switches off the heater, but
it also activates the timer function. You can change the required time with the
adjustment keys
H
THE INFORMATION DISPLAY
The information display ¹ not only serves as an indicator of the (set) time and
temperature (Sections C, E, and F), it also indicates any malfunctioning of the
heater. The code on the information display tells you what is the matter:
CODE
INFORMATION
e - 0
Temperature within the heater too high. Cool-down and re-ignite.
f - 0
Power interrupted.
e - 1
Faulty thermostat.
f - 1
Faulty burner thermistor.
e - 2
Starting problems.
and then the TIMER key
to set the time at which the heater must ignite.
once to clear the timer setting.
. The information display will show the CLOCK
, when you want to switch off the heater and ignite it
(refer to Section F).
immediately after that.
WHAT TO DO
Re-ignite the heater.
Contact your dealer.
Contact your dealer.
Contact your dealer.
4