Herunterladen Inhalt Inhalt Diese Seite drucken

Wamsler KF 198 50 Bedienungsanleitung Seite 23

Kaminofen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

may be only ember bed in the burning space, i.e. no flames may be
visible.
13. In heating mode, the surfaces, inspection glasses and handles may
become very hot. Warn children of these threats, and keep them away
from the fireplace when heated.
14. Ensure that the ashtray should be fully inserted, and in particular
never remove hot ash from the fireplace (fire risk).
15. In transitional periods, chimney draught may drop, resulting in the
imperfect suction of the generated flue gases. In such cases, the fire-
place is to be filled with smaller quantities of fuel, preferably wooden
chips or wood wool, and it is to be commissioned under control with
the stabilization of the chimney draught. The fire grate should always
be kept clean.
16. After the heating season, it is recommended to have the equipment
inspected by an expert. It is also advisable to clean the routes of flue
gases and pipes.
17. Should repairs or reconditioning be needed, please, contact your
dealer in a timely manner with the accurate specification of the article
and serial number. Only original Wamsler parts may be used.
18.
As the air needed for burning is drawn from the room where the fire-
place is located, ensure that sufficient air supply is received via the
gaps by the windows and external doors. Make sure that 4 m
should be provided to each kW of rated performance. For this fire-
place, it means that the room has to be at least 26 m in volume. If the
room is smaller, sufficient air supply can be secured by opening air
connections to other rooms with air openings (at least 150 cm
19. Ensure to keep proper lateral and rear distances from combustible
parts and materials. The associated values are specified in these user
instructions or the model plate.
20. The fireplace may not be modified.
21. The connection of the fireplace to the chimney is not permissible if the
effective height of the chimney is less than 4 m, or 5 m with multiple
loading. To the chimney that the fireplace uses, a maximum of two
other fireplaces, ovens may be connected.
22. In the event of any chimney fire, immediately close all the openings of
the equipment, and call the fire service. Never try to extinguish the fire
with water. Thereafter, always have the chimney inspected by an ex-
pert.
23
3
of air
2
).

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis