Description
The hand-held transmitter is part of the Opus
buttons A-D of the batteryless and maintenance-free transmitters consumers can be switched
wirelessly by the Radio Plus actuators. Each transmitter can simultaneously control an unlimited
number of actuators.
With two-button function the buttons A/B and the buttons C/D should be used as pairs (e.g.
A = OFF/UP and B = ON/DOWN).
The hand-held transmitters have a fixed address and must be programmed on a actuator. Refer
to the operating instructions for the Radio Plus actuators to learn how to use the Radio Plus
hand-held transmitter.
Button A
Button B
2. Ranges between transmitters and actuators
The range of the Radio Plus radio signals decreases as the distance between transmitter and
actuator increases.
If the normal range between transmitter and actuator is insufficient, an Radio Plus Repeater
(561.400) can be employed to increase range.
The range between the transmitter and actuator in a house is approx. 30m (line-of-sight
connection) and 100m in halls.
The transmission range depends on the materials used in the building:
Material
Typical range
Masonry
20m (max. 3 walls)
Reinforced concrete
10m (max. 1 wall/ceiling)
Drywall/wood
30m (max. 5 walls)
Limiting the range of the radio signals due to:
• Installing the transmitter or actuator in the immediate vicinity of materials with metal
constituents, or metal objects. A distance of at least 10 cm should be maintained.
• Installing the transmitter/actuator on the ground or at ground level.
• Moisture in the materials
• Devices, which also emit high frequency signals, such as e.g. computers, audio and video
equipment, electronic ballasts for illuminants. A distance of at least 0.5m should be maintained.
3.
Error analysis in the case of radio interference
For a new or pre-existing system:
• Check the system voltage of the actuator.
• Check if the actuator is receiving a radio command.
• Check if the actuator is connected as specified.
• Check the operation of the connected consumers.
• Delete all transmitters in the actuator, and reprogramme the actuator.
• Check if any changes have been made around the system that could generate problems
(metal cabinets, walls or furniture has been moved, etc.).
If possible, restore things to their original status.
• Mount the transmitter or actuator at a better location.
The actuator independently turns ON and OFF:
• This can occur when an outside transmitter is activated within the actuator range that was
previously programmed in the actuator.
• Delete all transmitters in the actuator, and reprogramme the actuator.
A transmitter does not work:
• Take the transmitter and move toward the actuator. If the system still works at a closer
distance, the transmitter was installed outside of the transmission range, or there
was interference.
• Mount the transmitter or actuator at a better location.
4.
Technical data
2SHUDWLQJ IHTXHQF\
 0+=
0RGXODWLRQ W\SH
$6. $PSOLWXGH 6KLIW .H\LQJ
&\FOHV RI RSHUDWLRQ
PLQ 
2SHUDWLQJ WHPSHUDWXUH
ƒ& WR ƒ& LQ GU\ URRPV
5HODWLYH KXPLGLW\

WR 
'LPHQVLRQV
ZLGWK PP [ OHQJWK PP [ KHLJKW PP
561444_Rev01_070206.pdf
four-way
-Radio Plus System by Jäger Direkt. With the
®
Button C
Button D
GB
5. Warranty
These operating instructions are an integral part of both the appliance and the terms of warranty.
They must be furnished to the user. The technical design of the appliance is subject to change
without prior notification.
Jäger-Direkt products are manufactured using state of the art technologies in compliance
with prevailing national and international regulations, and are quality tested.
The right of compensation apllies according to payment terms and delivery conditions of
Jäger Direkt GmbH & Co. KG.
Further information to application and parameterisation for the Opus radio plus product family
under www.opus-schalter.de.
Jäger-Direkt Radio Plus products may be sold and used in EU countries, Switzerland, Iceland
and Norway.
The products conform to R&TTE Directive 1999/5/EC and meet EU regulations.
GB - 1

Werbung

loading

Diese Anleitung auch für:

561.444