Herunterladen Diese Seite drucken

Safety Instructions; Application Area - Super-Flamm AERO Bedienungsanleitung

Indoor feuerstellen

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SafetY inStrUctionS

Disregarding these instructions may result in serious bodily harm!
Attention! The fireplace will get very hot!
Pay close attention to specified minimum distances (see page 4)
during operation.
Do not touch glass panes!
Device may only be operated by persons of legal age (18+) who
must have read and understood the instructions provided with
the device!
The indoor fireplace is not a toy!
Ensure that the indoor fireplace is correctly assembled before
operation (see assembly instructions)!
Operate fireplace only in rooms which comply with specifications
provided below!

application area

The device is only suitable for indoor use!
Pay close attention to operating conditions (see page 4)! Fire
hazard!
Device is not suitable as replacement for permanent heating.
Device is subject to national and local operating restrictions.
Device must be placed on a horizontal, stable, smooth and non-
flammable surface.
Device must not be placed in draft. Refrain from excessive
movement near the device.
Do not place flammable maerials, especially gasoline products,
near the device. Minimum distance of 160 cm must be observed!
fUel
Use BioEtahnol of at least 95 Vol.% exclusively. Fuel must be
approved for indoor fireplaces.
Use only small canisters (ie 1l bottles).
Attention! Fuel is volatile and there is a possibility of flammable
gases being produced (deflagration)!
Use included funnel to fill the device with fuel.
Take care not to spill fuel beside the firebox. Immediately wipe off
spilled fuel and rewipe with damp cloth.
Only use as much BioEtahnol as is necessary for desired burn-time
(1,0 l equal about 3 h).
Always let fuel burn off completely (danger of deflagration and
gas production).
If ingnition fails for 3 times in a row wait 15min before trying
again.
Use suitable means to empty firebox of excessice fuel before
ignition.
Do not make any modifications to the device!
Firebox must be fully cooled down before reigniting.
Make sure that no flame is still burning before reigniting!
Do not fill firebox with fuel while still burning or cooling down.
Observe normal safety measure for handling open flames!
Never leave pets unsupervised near the device.
Warning:
No other ambient air dependent fireplaces must be
operated in the same room!
Exception: Ambient air supply is warranted
Check safety container for spilled fuel before ignition and clean
it if necessary.
Do not leave the fireplace burning without supervision!
Always observe necessary distance to the device when igniting
fuel! Do not bend over the device when igniting!
firebox
Take care that assembly is carried out according to instructions.
The filling of the firebox (ceramic fibres) must not be damaged or
deformed in any way.
Firebox fuel level must not exceed level marked on inner box.
Ignite firebox only if correctly filled according to instructions on
page 3 (max. 1,6l)
Do not fill firebox with fuel while still burning or cooling down.
Observe 15min cool down time before reigniting firebox!
Device must not be ignited while still cooling down.
Ignition procedures on page 3 must be observed.
If reignition becomes necessary ensure that ignition accessory is
cooled down and no flame is still burning.
Do not operate with partially closed cover!
Use cover to extinguish flame (close cover completely).
If flame appearance changes stop operation and contact
customer support (firebox must be checked).
6

Werbung

loading

Diese Anleitung auch für:

PompeiSorrento