DMX-CONTROLLED OPERATION

You can control the spots individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.
For DMX-controlled operation set DIP Switch 10 to ON.
Addressing
Each device occupies 3 channels. To ensure that the control signals are properly directed to each device,
the device requires addressing. This is to be adjusted for every single device by changing the DIP-switches
as set out in the table below.
The starting address is defined as the first channel from which the device will respond to the controller.
Please make sure that you do not have any overlapping channels in order to control each device correctly
and independently from any other fixture on the DMX data link. If two, three or more device are addressed
similarly, they will work similarly.
Occupation of the DIP-switches:
Controlling:
After having addressed all LED FX Par-100 RGB DMX Spots, you may now start operating these via your
lighting controller.