Display
automatic
operating temp.
too hot
ESC
automatic
pressure sensor
failure
ESC
automatic
GSM module
failure
ESC
automatic
supply air
failure
ESC
automatic
cover open
ESC
automatic
check
combustion pan
ESC
automatic
check
airways
ESC
Possible cause of error
Flame temperature too high for long-
er period of time. Auger motor activation
may be defective.
Underpressure sensor defective or not
connected.
GSM module defective.
Connection error.
SIM card not inserted.
Insufficient credit.
Combustion air damper did not open in
the specified time.
Pellet tank cover was open too long.
Combustion pan slagged / overfilled.
Combustion pan not inserted / incorrect-
ly inserted.
A minimum vacuum pressure could not
be achieved in spite of the speed in-
crease of the induced draught fan.
Possible elimination
Request a service technician.
Request a service technician.
Request a service technician.
Check GSM module.
Check connection.
Insert SIM card.
Charge SIM card.
Check combustion air damper (cabling).
Close pellet tank cover.
Clean combustion pan.
Replace combustion pan.
Check combustion air line.