Herunterladen Diese Seite drucken

Siemens CVVA-IP Kurzanleitung Seite 2

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Englisch
Package contents
IP-Module CVVA-IP for fix dome cameras
Fixing template
2 fixing screws
2 wall plugs
2 mechanical screws
1 cable gland with 3/4" diameter
Software CD
Quick Start Guide (this document)
Important
This Quick Start Guide is only intended for use
by installers who have an adequate working
knowledge of video systems!
This guide outlines the most important
information about the vandal-proof fix dome
camera. It is, however, vital that you also refer to
the full User Manual.
IP-Module and fix dome
camera parts
See figure A, B and C
connector socket (3)
RJ45 socket (6)
two screws supplied (7)
fixing screw (9)
electrical supply cable connection
terminals (10)
BNC socket (11)
Y cable lead (12)
Y cable lead (13)
Installing the IP-Module
IP-Module fixing
The IP-Module features two apertures through
which you can feed the cables:
An aperture in the base
An aperture in the side
If you wish to use the side aperture:
Loosen the fixing screw (9) inside the IP-
Module.
Remove the blanking screw from the side
cable aperture and screw this into the
cable aperture in the base of the unit.
1.
Use the drilling template to drill two holes
in the ceiling/wall and insert the wall
plugs.
2.
If IP66 installation is required, use silicone
sealant to seal the joint at the base of the
IP-Module.
3.
Mount the IP-Module to the ceiling/wall.
4.
If vandal-proof installation is required,
protect the feed cables using suitable
protective conduits. Make sure you use a
suitable 3/4" conduit on the cable infeed.
Seal the threads as required.
5.
You can use the cable infeed
arrangement supplied (illustration C) for
other applications.
6.
Pass the cables (RJ45 LAN cable,
electrical supply cable and BNC cable)
through the desired cable infeed (side
aperture or base aperture).
7.
Connect the LAN cable to the RJ45
socket (6).
8.
Connect the Y cable supplied to the
connector socket (3) in the IP-Module.
9.
Schließen Sie das
Spannungsversorgungskabel an die
Anschlussbuchse (4) an.
10. If an analog video output is required,
connect the outgoing BNC cable to the
BNC connection line (5).
Installation and connection of the
dome camera
1.
Open the dome housing (illustration D).
2.
Gently pull the dome cables (electrical
supply cable and BNC cables) out of the
dome camera.
3.
Connect the Y cable lead (12) to the
dome camera video output.
4.
Connect the Y cable lead (13) to the
dome camera video input.
5.
Connect the (12 V DC / 24 V AC)
electrical supply to the electrical supply
cable connection terminal (10).
Warning
Ensure correct polarity if using a 12 V DC
supply, as incorrect connection may damage
the dome camera or cause the unit to operate
abnormally.
6.
Place the camera body on the IP-Module
and screw both units together using the
two screws supplied (7).
7.
Establish communication with the device
for the first time. See section 6:
Establishing initial communication with the
device.
8.
A test monitor can be connected to the
BNC socket (11) when configuring the
camera.
9.
Configure the dome camera as required.
Refer to the dome camera manual for set-
up instructions.
10. Place the dome back on the camera and
screw it in position.
Note
Clean the dome after installation using a soft,
lint-free cloth to remove dust and greasy
finger marks.
Operation and storage
Do not operate or store the unit:
At extremely hot or cold places.
Close to sources of strong magnetism.
Close to sources of powerful
electromagnetic radiation such as radios
or TV transmitters.
At humid or excessively dusty places.
Where exposed to mechanical vibrations.
Close to fluorescent lamps or objects
reflecting light.
Under unstable or flickering light sources.
Care and maintenance
The IP module CVVA-IP is maintenance-free.
Small amounts of dirt or dust can be cleaned
from the camera body using a clean soft cloth. If
the unit tends to get very dirty, the dome camera
should be placed within a protective housing.
Technical Data
General
Electrical supply
12 V DC/24 V AC
Power requirement
max. 6.0 W
Operating temperature
-10 – +50 °C, max.
relative humidity 90%
Storage temperature
-20 – +60 °C, max.
relative humidity 70%
Dimensions (H x Ø)
48 x 135 mm
Weight:
620 g
Material:
Aluminium
IP rating:
IP66

Werbung

loading

Diese Anleitung auch für:

2gf1185-8ag