English
5 Product information
5.1
Type key
Example: INOVA NH 25/40
INOVA NH
25
5.2 Technical data
Connection voltage
Energy efficiency index EEI *
Protection class IP
Water temperatures at max. ambi-
ent temperature of +40°C
Max. ambient temperature
Max. operating pressure
Min. inlet pressure at +95°C
* The benchmark for the most efficient circulators is EEI ≤ 0.20
5.3
Scope of delivery
• Circulation pump with gaskets
• Installation and operating instructions
6 Description and function
6.1
Description of the product
The pump (Fig. 1) consists of a hydraulic system, a glandless
pump motor with a permanent magnet rotor, and an electronic
control module with an integrated frequency converter. The
control module has a operating knob together with an LED dis-
play (Fig. 1) for setting all parameters and for displaying the
current power consumption in W.
24
High-efficiency pump
Threaded connection DN 25 (Rp 1)
1 ~ 230 V ± 10%, 50/60 Hz
See name plate
See name plate
–10°C to +95°C
–10°C to +40°C
6 bar
0.3 bar
Speck 07/2012