For Your Safety
Always inspect the plug and cable be-
fore use. If damaged, they must be re-
placed by a qualified professional.
Charge only WÜRTH batteries and use only
genuine accessories.
Keep the battery charger slot free of foreign ob-
jects and protect against contamination.
Protect battery charger against humidity and
operate only in dry areas.
Do not open the battery; protect against im-
pact, heat and fire. Danger of explosion!
When the battery is outside the battery charg-
er, cover battery terminals to avoid short circuits
from metal objects. Danger of fire and explosion!
Tool Specifications
Battery charger
Part number
Rated battery voltage (NTC)
Mains voltage
Charging current
Rapid charging
Trickle charging
Charging time
1.4 Ah
1.7 Ah
2.0 Ah
Degree of protection
Before Use
The mains voltage must comply with the specifica-
tions on the rating plate. 230 V battery chargers can
also be operated at 220 V.
The battery charger is only suitable for charging
NTC batteries from the Würth range of tools with volta-
ges between 7.2 and 14.4 V.
Use only genuine accessories.
Initial Operation
The charging process begins as soon as the mains
plug is inserted into the power supply socket and the
battery is placed into battery charger slot
ging process is indicated by green light
The "intelligent" battery charger recognises the char-
ged condition of the battery and switches a fully char-
ged battery immediately to trickle charging. By means
of this charging process, the battery is protected and
always fully charged.
Rapid charging is only possible when the temper-
ature of the battery is between 0 °C and 50 °C.
AL 60 U
702 343
7.2 V - 14.4 V
230 V
1.9 A max.
80 mA
approx. 50 min.
approx. 60 min.
approx. 71 min.
/ II
. The char-
.
Subject to change
A new battery-operated tool or one which has not
been used for an extended period achieves full perfor-
mance only after five charging and discharging cycles.
A substantial drop in operating period per charge in-
dicates that the battery
Indicators and Meaning
Continuous green light
Battery not inserted, mains voltage is on;
Continuous green light
Battery inserted, the battery charger is only deli-
vering a trickle charge because the battery is al-
ready fully charged, or ...
Battery inserted, the battery charger is only delive-
ring a trickle charge because the battery is too hot
(or too cold). The battery charger automatically
switches to rapid charging when a suitable tempe-
rature is reached.
Flashing green light
Rapid charging operates until the battery is fully
recharged. The battery charger then automatical-
ly switches to trickle charging.
Environmental Protection
Recycling raw materials instead of waste disposal
Machine, accessories and packaging should be sorted
for environment-friendly recycling.
These instructions are printed on recycling paper ma-
nufactured without chlorine.
The plastic components are labelled for categorized re-
cycling.
WÜRTH offers an environment friendly battery dispo-
sal service: Defective batteries are sent off to undergo
a complete recycling process.
Warranty and Service
The unit is maintenance free.
WÜRTH tools carry a guarantee of 12 months from
date of delivery.
Declaration of Conformity
We declare under our sole responsibility that this pro-
duct is in conformity with the following standards or
standardization documents. EN 50 144, EN 55 014
(Battery powered tools) and EN 60 335, EN 55 014
or EN 55 011, EN 60 555 (Battery charger) accor-
ding to the provisions of the regulations 73/23/EEC,
89/336/EEC, 89/392/EEC.
01
Adolf Würth GmbH & Co. KG
Rolf Bauer
must be replaced.
ppa. Otto Steck
5