Herunterladen Inhalt Inhalt Diese Seite drucken

Sharp XG-C40XU Service Anleitung Seite 5

Vorschau ausblenden Andere Handbücher für XG-C40XU:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

No.
Adjusting point
8
P SIGNAL
1. Connect the oscilloscope to
2. Make the following choice:
3. Using the horizontal 10-step
9
Sample and
1. Feed the XGA-mode 75-Hz
hold pulse
phase checking
2. Select the following group
10
RGB counter-
1. Feed the black-and-red
voltage
adjustment
2. Make the following choice:
11
RGB gradation
1. Feed the green-only SMPTE
regeneration
adjustment
12
RGB white
1. Feed the 32-step gray scale
balance
Adjusting conditions
TP1102 for red.
TP1202 for green.
TP1302 for blue.
Group : OUTPUT 2
Subject : PSIG-H
PSIG-L
signal, make sure no vertical
stripes appear every 12 dots.
(If any white or black vertical
stripes appear, finely adjust
the PSIG-L setting.)
black signal.
and subjects.
Group : OUTPUT3
Subject: SH-PHASE,
GCK-PHASE
(25%) stripe signal (XGA).
Group : OUTPUT 3
Subject : RC (R)
pattern signal (XGA).
Group : OUTPUT 1
Subject : G1-BLK
signal (XGA).
Group : OUTPUT 1
Subject : R1-BLK (R)
B1-BLK (B)
Adjusting procedure
» Adjust the PSIG waveform as shown below.
(With XGA signal input)
Adjust the PSIG-H setting.
2.3V 0.1V
GND
» Make sure that the (G) and (B) waveforms are similar
to that of (R).
» Make sure that the SH-PHASE and GCK-PHASE
settings are 11 and 6, respectively.
» Using the control switches or the remote controller
buttons, adjust the data in order to minimize the
flicker.
» Make the same adjustment for BC (B), GC (G).
» See if the image is equally adjusted at the center
and both sides of the screen. If not, readjust the
setting to have the image equal at right and left.
» Adjust the G-BLK data until the gradation of the
portion 1 (95% and 100% white) shown below
can be slightly recognized. Make sure also that the
gradation of the portion 2 (0% and 5% black) is
visible.
2
» Choose the subjects R1-BLK and B1-BLK and
adjust the black balance of the gradation.
5
XG-C40XU
1
(
XG-C40XE
(
1
Adjust the PSIG-L setting.
3.7V 0.1V
1
)
)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Xg-c40xu1xg-c40xeXg-c40xe1

Inhaltsverzeichnis