6. Specifications

6-1. Electrical Specifications

Power consumption 1.0 W
Input format
-B1: Source input (+COM)/-B2: Sync input
(–COM)
Photocoupler insulation
supply DC +5 to +24 V
Output format
-B1: Sync output (–COM)/-B2: Source
output (+COM)
Photocoupler insulation
supply DC +5 to +24 V
Input signal
Data request (DRQ), input request (LRQ),
counter module (channel) number,
measuring mode selection, comparator set
selection
reference point load
Output signal
6-digit BCD data, polarity sign, Go/No Go
judgment output, READY, alarm, reference
point acquired
(*2)
Output setting
Output mode OUT/OR/Timer mode
4, 8, 16, 32, 64, 128 ms
MG30-B1 / MG30-B2
External power
External power
(*1)
, reset, start/latch, pause,
*3
(1, 2,
(*5)
*4
), Output logic
Miscellaneous
Operating temperature and
humidity range
Storage temperature and
humidity range
Mass
*1: The comparator value setting is set to the MG10 main module
over a RS-232C connection.
*2: This is set by the setting switches on the MG30.
*3: Change the channel number and read out the data in every
output mode.
*4: The timer output interval fluctuates depending on the unit
configuration and the presence of input/output besides BCD
output.
If there is no input/output besides BCD output, the fluctuation
for all timer settings is ±0.1 ms.
*5: When the BCD output logic is "+", the value of "0" is indicated
by "L"(ON) for all of the BCD × -1/2/4/8 bit outputs and by
"H"(OFF) when "–".
The valid range for BCD output logic is BCD output data
(BCD1-1 to BCD6-8), polarity signs (SIGN), and comparator
Go/No Go judgment output (U-NG, GO, L-NG). The logic for
other input/output data is fixed.
When the BCD output logic is "+", the + polarity sign is
indicated by "L"(ON) and – polarity sign is indicated by
"H"(OFF). When the BCD output logic is "–", the + polarity
sign is indicated by "H"(OFF) and – polarity sign by "L"(ON).
0 to +50 °C (No condensation)
–10 to +60 °C (20 to 90 % RH)
100 g
(E)
13