Herunterladen Inhalt Inhalt Diese Seite drucken

HEIDENHAIN POSITIP 880 Installationsanleitung Seite 11

Vorschau ausblenden Andere Handbücher für POSITIP 880:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
POSITIP 880
Installation Instructions
Complete Operating Instructions available at www.heidenhain.de
Data interface connections
Notice
This product contains components that can be damaged by electrostatic
discharge (ESD). Observe precautions for handling ESD sensitive devices and
never touch connector pins unless properly grounded.
Connecting an encoder
This product can be used with HEIDENHAIN linear, and rotary encoders that provide
sinusoidal output (11 µA
or 1V
PP
must not exceed 30 meters in length.
To connect an encoder:
Verify that the power switch is in the off position.
X
X
Connect the axis encoder tightly to it's connector. An input designator is provided near
X
X
each connector located on the rear of the product.
Connecting an RS-232-C cable
The RS-232-C port is used for bi-directional communication with a computer. A cross-
over cable must be used. Refer to the POSITIP 880 Operating Instructions for more
information on RS-232-C communications.
To connect an RS-232-C cable:
Verify that the power switch is in the off position.
X
X
Connect a computer's RS-232-C port to the POSITIP 880 RS-232-C port (X31) located
X
X
on the rear of the product. Use the HEIDENHAIN cable ID 366964-xx.
Connecting the IOB 89
The IOB provides digital inputs and outputs.
To connect the IOB 89:
Verify that the power switch is in the off position.
X
X
Connect the IOB 89 using the connecting cable to the POSITIP 880 using X51. Use the
X
X
HEIDENHAIN cable ID 532856-xx. See Accessories section for more details.
Parallel port
The parallel port allows printing to a printer that supports Centronics interface. Refer to the
POSITIP 880 Operating Instructions for more information on the parallel port X32.
To connect a printer cable:
Verify that the power switch is in the off position.
X
X
Connect a printer cable to the POSITIP 880 X32 located on the rear of the product.
X
X
Connecting the KT 130 Edge Finder
The KT 130 Edge Finder is used for probing functions.
To connect the KT 130 Edge Finder:
Verify that the power switch is in the off position.
X
X
Connect the KT 130 Edge Finder directly to the POSITIP 880 using X10 located on the
X
X
rear of the product. See Accessories section for more details.
) signals or EnDat (Encoder Data). The connecting cable
PP
Observe ESD handling precautions
6
X1 thru X6 - 11 µApp/1 Vpp/EnDat
7
X31 -
- RS-232-C
11
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2
37 36 35 34 33 32 31 30
29 28 27 26 25 24 23 22 21 20
X51 - IOB 89
4
13 12 11 10 9 8 7 6 5 4 3 2
1
25 24 23 22 21 20
19 18 17 16 15 14
X32 -
- RS-232-C
5
X10 - KT 130
1
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis