INNOCIGS EVIC PRIMO – ERROR MESSAGES & PROTECTIONS

Weak Battery

When the power output of the batteries drops below 2.9 V, the display will read "WEAK BATTERY". The output power will be
reduced to match the voltage output of the batteries.
Charge Batteries
If the power of the battery is lower than 10%, the power symbol will flash on the screen.
Imbalanced Batteries
If the voltage difference between two cells is ≥ 0.3 V, the device will display "IMBALANCED BATTERIES" when plugged in. Please
fully charge the cells or replace them with freshly charged cells.
Charge Error
When no current is detected in charging state, the screen will display "CHARGE ERROR".
Check Battery
If the cells are installed incorrectly, the screen will display "CHECK BATTERY".
Check USB
If the voltage of the USB charger is ≥ 5.8 V, the device will display "CHECK USB ADAPTER" when plugged in or vaping.