Herunterladen Inhalt Inhalt Diese Seite drucken

Installation - Atag WD1674M Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für WD1674M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INstallatION

Prior to connecting the drawer, ensure that all cables in your
home's electrical system are of sufficient diameter to supply the
appliance properly. Your system should be protected by a 10-amp
fuse.
The power circuit should have a bipolar power failure mechanism with
contact gaps of at least 3 mm.
Complete all electrical connections before building in the appliance.
The drawer should be connected via a (normalised) power cable with
3 x 1 mm² conductors (1 phase + 1 N + earth) to single phase
220 - 240 V~ mains power, via a 1 phase + N + normalised earthing
CEI 60083 plug socket or in accordance with local installation
regulations. The earth wire (green/yellow) should be connected to the
appliance's connector clamps and with the electrical system's earth.
If the appliance is connected to a plug socket, this must remain
accessible after the drawer has been installed.
The warming drawer's neutral conductor (blue wire) should be
connected to the mains power neutral conductor.
EN 8

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wd1692dWd1611d

Inhaltsverzeichnis