Mounting a Power Supply Cable
Opening the terminal board:
V
Remove the "V" screw;
Pull to open the cover of the terminal board.
To install the cable, proceed as follows:
Remove the wire clamp screw and the three contact
screws L-N-
Fasten the wires beneath the heads of the screws using
the following color scheme : Blue (N) Brown (L) Yellow-
Green
Fasten the suppy cable in place with the clamp, close the
cover to the terminal box and fasten it with the "V" screw.
Inner Dimensions of the Oven:
Width:
Depth:
Height:
Inner Volume of the Oven:
Energy Consumption:
°
To reach 200
C:
To maintain the temp. at 200
Total:
Voltage and Frequency of Power Supply:

Technical Specifications

40 cm
39 cm
34 cm
51 Liters
0.45 kWh
°
C for 1 hour:
0.7 kWh
1.15 kWh
230V / 50Hz / 2100W
Attaching the Power Supply Cable to the Mains
The appliance must connected directly to the mains by
means of an omni-polar switch with a minimum contact
break of 3 mm, sized for the load and in compliance with
the standards currently in effect (the earthing wire must
not be interrupted by the switch).
The power supply cord must be positioned so that it does
not reach a temperature 50
re at any one point.
Before making the connection, check that:
the fuse and the electrical system in the home can
handle the load of the appliance (see the data plate);
the electrical mains in the home are equipped with an
efficient grounding system in compliance with the safety
standards currently in effect;
The electrical outlet or omnipolar switch is within easy
reach when the oven is installed.
NB: Do not use adaptors, shunts or reducing devices as
they may cause overheating and lead to fires.
This appliance conforms with the following European
Economic Community directives:
-
73/23/EEC of 19/02/73 (Low Voltage) and subsequent
modifications;
-
89/336/EEC
of
Compatibility) and subsequent modifications;
-
93/68/EEC of 22/07/93 and subsequent modifications.