Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Light Bulbs - Siemens LI 48932 Gebrauchsanleitung Und Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Replacing the light bulbs

1. Switch off the extractor hood and pull
out the mains plug or switch off the
electricity supply at the fuse box.
When switched on, the halogen bulbs
become very hot. Even for some time after
the bulbs have been switched off there is
still a risk of burns.
2. Remove the bulb ring with a screwdriver
or similar tool.
3. Replace the halogen light bulb
(conventional halogen bulb, 12 Volt,
max. 20 Watt, G4 cap).
Caution: Refer for plug-in lampholder.
Take hold of the bulb with a clean cloth.
4. Re-insert the bulb ring.
5. Plug the appliance into the mains or
switch it on at the fuse box.
Note: If the light does not function, check
that the bulbs have been inserted correctly.
Moving the operating unit
You can move the operating unit from
the middle of the filter drawer to the left
or right side.
The operating unit can also be fitted at the
front in a handle moulding available as an
optional accessory or in the enclosed
handle moulding (see optional accessories
on back page).
1. Loosen the 2 screws from below.
2. Remove the operating unit and discon-
nect the plug from the ribbon cable.
3. Remove the side cover from the filter
drawer.
4. Connect the plug of the side ribbon
cable to the operating unit.
5. Insert the operating unit into the side of
the filter drawer.
Insert the excess ribbon cable.
6. Insert the cover into the middle of the
filter drawer and screw on the cover from
below with 2 screws.
Setting the saturation indicator
If the operating mode is to be switched
over (exhaust air/circulating air mode), the
saturation indicator for the filters must also
be switched over (see Installation
instructions).
Faults
#
ã
If
or
is displayed:
❑ See "Filters and maintenance" Section.
If the extractor hood cannot be
operated:
❑ Isolate the extractor hood for approx.
1 minute by pulling out the mains plug or
switching off the fuse.
Then switch on again..
If you have any questions or if a fault
occurs, please call Customer Service.
(See list of Customer Service
representatives).
When you call, please quote the following:
E-Nr.
FD
Enter the numbers in the above box. The
numbers can be found on the rating plate
inside the extractor hood following removal
of the grease filters.
The manufacturer of the extractor
hoods accepts no liability for complaints
which can be attributed to the design
and layout of the pipework.
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis