Herunterladen Inhalt Inhalt Diese Seite drucken

Front Panel - Sterling Power USA BB122470 Benutzerhandbuch

Vorschau ausblenden Andere Handbücher für BB122470:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Front Panel

11
10
12
9
8
7
6
5
4
3
2
1
Models:
BB1260 / BB122470 / BB123670 / BB124870 /
BB242435 / BB241235 / BB123670 / BB124870
Front label display
1 & 26)
ENTER / SETUP and SELECT buttons, used to
adjust settings.
2 & 25)
Background light for button, used also to show
unit is operational.
3)-11)
The left column of LEDs have 3 different
functions. Firstly, on unit start up the battery type is
displayed. Secondly, after startup it becomes an input
voltmeter. Thirdly, during custom setting the voltage
scale is used to set the voltage - refer to later.
12)
This LED has 3 meanings. Firstly, when on battery
type selection mode this is the LiFePO
indicator. Secondly, on default mode (most times) this
shows the charger is on fast charge mode. Thirdly, if
flashing, then the unit is in standby and was in fast
charge prior to entering standby.
13-15)
These LEDs show the battery charge
progression through its cycle.
15)
Flash when in standby.
16-24)
Has 3 functions: Firstly, on start up they show the
output voltage. Secondly, if an alarm is present the alarm
shows up. Thirdly, this row is used in the custom setup
procedure to set timing functions, voltages and time
factors. Its general function is as an output voltmeter, in
the event 2 LEDs are on the voltages is between the 2
settings, if the top or bottom red LED is on then the
voltage is outside the parameters off the voltmeter.
16)
High voltage, if on solid it is high output voltage, if
flashing it is high input voltage.
13
14
15
Regen timer off (S) / on (fl)
High bat temp (fl) SVEM (S)
28
27
lithium battery
4
4
11
16
10
17
9
18
8
19
7
20
6
21
5
22
4
23
3
24
16
25
17
26
18
20
19
21
22
24
17)
High temp trip, if flashing then high unit
temperature trip.
18)
No faults (solid on). Power Pack mode / live
voltage output (flashing).
19)
No regen. mode or regen. timer at 0 = solid LED.
Regen on / timer on = flashing LED.
20)
Remote Battery sense cable connected (solid).
21)
Battery sense voltage drop in cable outside the
prescribed 1.5V drop maximum, thicker cable
required - LED flashing.
22)
Device's power ability reduced due to high
ambient temperature or voltage drop in output cable
to big. Alarm will be in conjunction with other
information alarm. If flashing unit is in night mode
with reduced power and low fan speed.
23)
Low voltage alarm, low voltage on input =
flashing LED. Input alternator not supplying enough
power or failed. Low voltage output = solid LED.
Something consuming a lot of power or unit not
working. No voltage output then LED on solid.
24)
If flashing then battery temperature too high.
Solid LED is in SVEM mode - Stationary Vehicle
Engage Mode.
27)
Numbers relating to battery custom setup (if
used) this is the charge factor number.
28)
Numbers relating to custom setup mode these
numbers relate to timing, i.e. maximum and
minimum time settings.
12
13
14
15
Regen timer off (S) / on (fl)
High bat temp (fl) SVEM (S)
1
23
Model:
BB1230
BB122440
26

Werbung

Inhaltsverzeichnis
loading