Features
Brillant LED display
Control BCD or binary, parallel or multiplex
PLC compatible
Extended character set
Parameterization via menu
Plug-in screw terminal strip
Block diagram
Display range
Depending on the unit version, the units show the following number of digits:
S202-x2/06/0x-001/0B-P0 (2 digits):
S202-x3/06/0x-001/0B-P0 (3 digits):
S202-x4/06/0x-001/0B-P0 (4 digits):
S202-x5/06/0x-001/0B-P0 (5 digits):
Signal voltage
The data inputs are PLC compatible and dimensioned for the following signal
voltages:
L-Signal = -3.5...+5 V, H signal = +18...30 V (active H)
Open input = L signal, M = reference potential
24
C2...C1
C3...C1
C4...C1
C5...C1
BAL S202 PAR M 1.0