Herunterladen Inhalt Inhalt Diese Seite drucken
Lake People SRC F42 Bedienungsanleitung

Lake People SRC F42 Bedienungsanleitung

20 bit sample-rate-converter
Vorschau ausblenden Andere Handbücher für SRC F42:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SRC F42
20 BIT SAMPLE-RATE-CONVERTER
Bedienungsanleitung
User´s manual
Technical specifications
Pro / Con Bit-Settings
Schaltpläne
Schematics
Lage der Bauelemente
Component layout
Konformitätserklärung
L A K E P E O P L E
HAIDELMOOSWEG 52 D-78467 KONSTANZ TEL: 07531/73678 FAX: 07531/74998
Seite/Page
2
5
8
9
10
10
13
13
15
DATE: III/98
1

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Lake People SRC F42

  • Seite 1 SRC F42 20 BIT SAMPLE-RATE-CONVERTER DATE: III/98 Seite/Page Bedienungsanleitung User´s manual Technical specifications Pro / Con Bit-Settings Schaltpläne Schematics Lage der Bauelemente Component layout Konformitätserklärung L A K E P E O P L E HAIDELMOOSWEG 52 D-78467 KONSTANZ TEL: 07531/73678 FAX: 07531/74998...
  • Seite 2 ALLGEMEINES DIE STROMVERSORGUNG Der LAKE PEOPLE SRC F42 besteht aus einer Die Stromversorgung erfolgt über eine einge- Sync-Einheit und ein oder zwei asynchronen baute IEC-CEE Kaltgerätedose mit einem inte- Sample-Rate-Convertern (SRC) höchster Quali- grierten, von außen zugänglichen Sicherung- tät. halter.
  • Seite 3 "ERROR“ LED und das Leuchten der grü- nen "LOCK“ LED angezeigt. HINWEIS: Die Sample-Rate der aktivierten Sync-Quelle Der SRC F42 kann zwei SRC-Einheiten auf- wird zusätzlich über drei gelbe LEDs für "48, nehmen. Die getätigten Einstellungen an der 44,1 und 32 kHz“ angezeigt, sofern die gemes- Sync-Einheit gelten immer für beide SRC´s.
  • Seite 4: Die Funktion

    - Die korrekte Funktion des SRC wird über die grüne LED "LOCK“ angezeigt. DIE DIGITALEN AUSGÄNGE Der SRC F42 stellt je einen symmetrischen, ko- axialen und optischen Ausgang pro SRC Ein- heit zur Verfügung. Das Datenwort (Professi- onal- oder Consumerformat) ist an allen Aus- gängen gleich, unabhängig von der Norm oder...
  • Seite 5 Active status is indicated by an LED next to the GENERAL INFORMATION power switch. A generously dimensioned power supply delivers the internal supply voltages. The LAKE PEOPLE SRC F42 consists of a sync unit and one or two asyncronous sample- rate converters of highest quality. POWER-UP...
  • Seite 6 HINT: Additionally, the sample frequency of the activa- The SRC F42 is intendend to bear up to two ted sync source is displayed by three yellow SRC- units. All settings of the Sync-unit are va- LED´s "48, 44.1 or 32 kHz“, when the detected lid for both SRC units.
  • Seite 7 - Byte 1, Bit 7 = 0 = original / pre-recorded data THE DIGITAL OUTPUTS Each SRC-unit of SRC F42 is equipped with a balanced, coaxial and optical output. The digital output word is identical, regardless of their phy- sical and electrical standard. The outputs are si- tuated on the rear panel.
  • Seite 8: Technical Specifications

    TECHNICAL SPECIFICATIONS (All measurements A-weighted, 20 Hz... 20 kHz, referred to digital full scal) SYNC UNIT Internal Oszillators: 44.1 / 48 kHz AES Sync Input: transformer balanced via XLR according to AES 11-1995 Impedance: 110 ohms Lock Range: 28 ... 56 kHz WCLK Sync Input: unbalanced, TTL level (0.5 V min.) Impedance:...
  • Seite 9 CHANNEL STATUS BIT SETTINGS PROFESSIONAL MODE CONSUMER MODE BYTE 0 BYTE 0 Pro / Con Pro / Con Consumer use Consumer use Professional use Professional use Audio/Non Au- Audio/Non Audio Normal Audio Normal Audio Non-Audio Non-Audio Signal Em- Copy / Copyright phasis not indicated Copy inhibited...
  • Seite 15: Konformitätserklärung

    KONFORMITÄTSERKLÄRUNG Hiermit wird bestätigt, dass die elektrische Anlage / das elektrische Betriebsmittel den unten aufgeführten Bestimmungen entspricht. Bezeichnung: SAMPLE-RATE CONVERTER Typ: SRC F42 Seriennummer: - alle - Baujahr: ab 1998 EG RICHTLINIEN: Niederspannungsrichtlinie 73/23/EWG Elektromagnetische Verträglichkeit 89/336/EWG HARMON. REGELN DER TECHNIK...

Inhaltsverzeichnis