Herunterladen Inhalt Inhalt Diese Seite drucken

Installation - Oase Pondovac 4 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für Pondovac 4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Pos: 107 /Alle Produkte/Ueberschriften/5. H1 Montage @ 7\mod_1202907725390_121.doc @ 43908 @ @ 1

Installation

Pos: 108 /Pumpen/Schlammsauger/Pondovac 4/Montage1::Vorbereitung @ 20\mod_1285154425240_121.doc @ 123369 @ @ 1
Preparation (Fig. C, D, E):
− Fit the wheels (11) on the housing.
− Bring the transport brace (12) into the desired position. For this purpose, loosen and retighten the hand screw (13).
− Fit the intake distributor (4) into the inlet (14) by performing a plug-turn movement (bayonet closure).
− Connect the suction hose (2) to the intake distributor (4).
− Fit the extension tube (Fig. A, 6, 7) at the hand-held nozzle of the tube (2). The transparent tube (6) allows a flow
control to be able to detect blockages earlier.
− Slide on the tool (9, 10) appropriate for the task.
Note: The higher the number of tubes used, the higher the tube frictional resistance. This leads to a reduction of the
suction capacity.
Pos: 109 /Pumpen/Schlammsauger/Pondovac 4/Montage2::Betrieb als Schlammsauger( I) @ 21\mod_1285686764857_121.doc @ 124393 @ @ 1
Operation as a sludge suction unit (Fig. B, E)
Note: When the unit is used as a sludge suction unit, the waste water is directly drained through the drain ho-
se (Fig. B, 3). The water is not collected in the container.
Pos: 110 /Alle Produkte/Ueberschriften/H4 So gehen Sie vor: @ 21\mod_1285675922044_121.doc @ 124057 @ @ 1
How to proceed:
Pos: 111 /Pumpen/Schlammsauger/Pondovac 4/Montage3::Betrieb als Schlammsauger (II) @ 20\mod_1285154441178_121.doc @ 123397 @ @ 1
− Place the unit at a minimum distance of 2 m from the water.
− Route the drain hose (3) with a slight gravity: Places the unit slightly higher. Ensure a safe and stable position.
Ensure that the drain opening (15) is above the water level.
− Plug the drain hose (3) into the drain opening (15) of the collection container.
− Ensure that the hose lies straight: Avoid kinks or bends caused by unevenness of the ground. Allow unrestricted
draining of the water, which has to be disposed of in accordance with the local conditions.
Note: When you pull the dirt catcher bag (Fig. A, 8) over the free end of the drain hose (3), you can return the water,
then free from coarse particles, such as dead leaves or algae, into the pond. As an alternative, the removed pond
sludge can be used as plant fertiliser. In this case, lay the drain hose directly on a plant bed. Otherwise dispose of in
accordance with the local conditions.
Pos: 112 /Alle Produkte/Dummy_module/===== Abstand 3 pt ===== @ 11\mod_1251901846864_0.doc @ 72826 @ @ 1
Pos: 113 /Pumpen/Schlammsauger/Pondovac 4/Montage4::Betrieb als Nasssauger (I) @ 21\mod_1285685446918_121.doc @ 124278 @ @ 1
Use as a wet vacuum cleaner
Note: When using the unit as a wet vacuum cleaner, the waste water is collected in the container. A maximum of 10 l
of fluid can be taken in.
Pos: 114 /Alle Produkte/Ueberschriften/H4 So gehen Sie vor: @ 21\mod_1285675922044_121.doc @ 124057 @ @ 1
How to proceed:
Pos: 115 /Pumpen/Schlammsauger/Pondovac 4/Montage5::Betrieb als Nasssauger (II) @ 20\mod_1285234309525_121.doc @ 123513 @ @ 1
− Place the unit at a minimum distance of 2 m from the water (Fig. B).
− Seal the drain opening (15) of the collection container by means of the plug (Fig. C, 5).
Pos: 116 /Pumpen/Schlammsauger/Pondovac 4/Montage::Düsenverwendung @ 20\mod_1285231176549_121.doc @ 123457 @ @ 1
Use of the tools (Fig. A, 9, 10):
Universal tool (a): To remove pond sludge without taking in the pond gravel.
Thread algae tool (b): For the separation and removal of thread algae.
Bristle tool (c): For the removal of stubborn soiling.
Large tool (10): For cleaning large, level surfaces.
Wet suction tool (d): Only to be used when operating the unit as a wet vacuum cleaner to remove soiled water or
residual water.
Note: Always work slowly, performing smooth, uniform movements. This largely prevents sediments from being swirled
up.
Pos: 117 /Alle Produkte/Dummy_module/===== Abstand 6 pt ===== @ 7\mod_1196627997106_0.doc @ 41651 @ @ 1
Pos: 118 /Alle Produkte/Ueberschriften/7. H1 Inbetriebnahme @ 7\mod_1196625111244_121.doc @ 41417 @ @ 1
Start-up
Pos: 119 /Pumpen/Schlammsauger/Pondovac 4/HINWEIS Pondovac4 Gerät nie ohne Filterschaum und Schwimmer betreiben! @ 21\mod_1285675225566_121.doc @ 124001 @ @ 1
Attention! Never operate the unit without foam filter (Fig. H, 22) or float body! Both are fitted when delivered. Never
vacuum dust or dirt!
Pos: 120 /Pumpen/Schlammsauger/Pondovac 4/Inbetriebnahme Pondovac 4 @ 20\mod_1285232113606_121.doc @ 123485 @ @ 1
Connect the unit to the power supply. The unit is equipped with a power switch (Fig. F, 16):
Position I: Automatic mode. Continuous operation.
Position 0: The unit is switched off.
Pos: 121 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @ @ 1
- GB -
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis