2. Your body water in %
(TBW)
3. Your muscle mass in %
(MUS)
4. Your bone mass in kg
(BONE)
*** While the proportion of body fat is being shown, at the very bottom of the display
appears an evaluation:
After that your measured values (weight, body fat, body water, muscle mass
and bone mass) will be shown to you in turn, 3 times in succession.

Display error Messages

NOTE:
If an error message appears on the display, wait until the device is turned off.
Turn it on again to restart the operation. If the error display has not
disappeared, take the batteries out of the battery compartment for 10 seconds.
"EEEE" = Overload indicator – the maximum capacity of the scales (180 kg)
has been exceeded. Remove the load from the scales immediately, otherwise
the load cell could incur damage.
Or: Faulty weighing or measuring process – e.g. when the scales are not
standing stably or you are not standing still on the weighing platform.
"Lo" = Batteries are empty – please replace the batteries with the battery type
intended for your scales (4 x 1.5V AAA).
"Err" = The body fat proportion is either too low (below 5% cannot be shown)
or the body fat proportion is too high (over 50% cannot be shown).