Herunterladen Diese Seite drucken

Renkforce 1404109 Bedienungsanleitung Seite 2

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

G Operating instructions
Thermo-/Hygro Analogue Comfortmeter
Item no.
1404109
Intended use
The product is used to measure temperatures in degree Celsius (°C) as well as to
indicate the relative air humidity (RH%); it is designed to be mounted on a wall for
measurements indoors or at sheltered outdoor locations.
These products comply with the applicable National and European requirements. All
names of companies and products are the trademarks of the respective owners. All
rights reserved
Package contents
• Meter
• Operating instructions
Up-to-date Operating Instructions:
1. Open www.conrad.com/downloads in a browser or scan the
displayed QR code.
2. Select document type and language and enter the item num-
ber into the search field. After submitting the query you can
download displayed records.
Safety instructions
Damage due to not following these operating instructions will void the
warranty! We do not assume any liability for any resulting damage!
We do not assume any liability for material and personal damage caused
by improper use or non-compliance with the safety instructions. In such
cases, the warranty will be null and void.
• For safety reasons, any unauthorised conversion and/or modification to
the product is not permitted.
• Never use the meter outside its specifications (see „Technical data")
• The product is not a toy and should be kept out of the reach of children.
• Manufacturers and distributors are not responsible for any incorrectly
measured values and any consequences thereof.
• The product is intended as an indicator of temperature and humidity for
home use only and absolute accuracy cannot be guaranteed.
• This product may not be used for medical purposes or for public informa-
tion.
• Do not leave packaging material carelessly lying around, since it could
become a dangerous plaything for children.
• Handle the product with care; impacts, blows, or accidental falls, even
from a low height can damage it.
Assembly
Select an installation site which is not exposed to direct sunlight or, if indoors, to di-
rect heat (faulty temperature and humidity readings). The location for the installation
outdoors should also be sheltered from precipitation, in order to avoid biased results
when measuring. Do not use the meter in or under water, this will ruin it.
Installation is carried out as follows:
Drill a screw (not included) into the desired wall with the head of the screw protruding
about 5 mm from the wall. The screw head must be so large that it cannot slip through
the hole of the suspension eye. Hang the unit by the rear suspension eye carefully on
this screw.
A wall mount is only possible on vertical plane walls. Make sure that the
product is safely hanging on the screw before letting it go.
Thermometer and hygrometer
The thermometer measures the temperature in degrees Celsius. The hygrometer
measures the percentage of moisture in the air. This value is "relative" because de-
pending on the temperature the air can hold various large amounts of moisture.
The thermometer and hygrometer displays come with factory preset set-
tings. To adjust the temperature and hygrometer you compare the numbers
with a correctly functioning reference instrument. Deviations on the pointer
can be corrected by gently turning the adjustment screw on the back.
Living environment
If the air in the room is too warm and too dry it is bad for your health, especially for your
skin and respiratory tract. The right temperature and humidity play a role in plants,
wood floors, antique furniture, musical instruments and books.
By controlling the indoor environment you feel more comfortable and save on heating
costs. The right temperature and humidity vary with use from room to room. The fol-
lowing guidelines are recommended:
Staircase
15 °C
Bedroom
16 - 18 °C
Kitchen
18 - 20 °C
Living room
20 - 22 °C
Bathroom
23 °C
Handling
• First, allow the product to reach room temperature. This may potentially take several
hours.
• The housing may not be opened!
• Avoid the following unfavourable environmental conditions at the installation loca-
tion or during transportation:
- Dust or flammable gasses, fumes or solvents
- Strong vibrations
- Strong magnetic fields, as can be found near machines or loudspeakers
Cleaning
Only a soft, damp cloth may be used for cleaning the display and housing. Never use
solvent-based or abrasive cleaning agents. Do not use the device in or under water!
Disposal
Please dispose of the unserviceable product according to the relevant stat-
utory requirements.
Technical data
Temperature
Measurement range .......................... -30 °C to +50 °C
Tolerance ............................................. ±1% at +10 °C to+30 °C (other areas 2%)
Air humidity
Measurement range .......................... 10% to 100%
Tolerance ............................................. ±5%
Dimensions (Ø x D)............................. approx. 198 x 23 mm
Weight .................................................. approx. 450 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2015 by Conrad Electronic SE.
at 40 - 60% humidity
at 50 - 70 % humidity
at 50 - 70 % humidity
at 40 - 60 % humidity
at 50 - 70 % humidity

Werbung