Herunterladen Inhalt Inhalt Diese Seite drucken

VGE XCLEAR UV-C PRO 75 000 AMALGAM Bedienungsanleitung Seite 6

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
"UP" means (up): This option enables you to increase the meter indication to the desired
EN
hour indication.
This selection is confirmed if the selected user setting "UP" and the meter indication on
the display blink alternately. Following this, press the switch (R) down for 5 seconds. After 5
seconds, the display will only indicate "UP". You can then release the switch.
By briefly pressing the switch, the counter value can now be increased in steps of 500 hours
from the value of 4500 up to a maximum value of 9999. The increased value and "UP" will
blink alternately on the display.
After you have selected the desired hour indication, wait for 10 seconds. After 10 seconds,
the selected hour indication will be displayed and the Pro will start counting down.
If you make a mistake while increasing the meter indication, it is possible to reset the
counter to 4500 by keeping the switch pressed down for 5 seconds. The counter value will
then be reset to 4500, and a new value can be set.
"dn" means (down): This option enables you to decrease the meter indication to the
desired hour indication.
This selection is confirmed if the selected user setting "dn" and the meter indication on
the display blink alternately. Following this, press the switch (R) down for 5 seconds. After 5
seconds, the display will only indicate "dn". You can then release the switch.
By briefly pressing the switch, the counter value can now be decreased in steps of 500
hours from the value of 4500 down to a minimum value of 0000. The decreased value and
"dn" will blink alternately on the display.
Once you have selected the desired hour indication, wait for 10 seconds. After 10 seconds,
the selected hour indication will be displayed and the Pro will start counting down.
If you make a mistake while decreasing the meter indication, it is possible to reset the
counter to 4500 by keeping the switch pressed down for 5 seconds. The counter value will
then be reset to 4500, and a new value can be set.
The time meter will indicate in the following manner that the lamp must be replaced:
From hour position 0672; the display will blink every second. The lamp is to be replaced in
4 weeks' time.
From hour position 0336; the display will blink every half second; The lamp is to be
replaced in 2 weeks' time.
From hour position 0168; the display will blink every ¼ second; The lamp is to be replaced
in 1 week's time.
At an hour position of 0000; the digits will blink continuously, and the meter will not
continue to count down. The lamp must be replaced.
DISMANTLING / MAINTENANCE
Always switch off the power supply during maintenance/dismantling of the device.
The device must be cleaned twice a year. If there is an increase in algae and/or scale, the
|
6

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für VGE XCLEAR UV-C PRO 75 000 AMALGAM

Diese Anleitung auch für:

Xclear uv-c pro 150 000 amalgam

Inhaltsverzeichnis