- Sufficient clearance (50 cm minimum) for the optimal operation and disassembly of the panels is
provided around the
- Make sure that the air flow (grid inlet and outlet) is not obstructed by any objects or back flow. The
performance of the heat pump may be reduced and it may even be switched off for safety reasons. Refer
to the chapter "Maintenance for cleaning".
- The water flow through the pump is driven by the pool filter pump (or an auxiliary pump). The
recommended water flow for each pump is shown in the table of specifications and on the label on the
side of the heat pump.

HYDRAULIC CONNECTIONS

Diagram
Filter
Reminder :
The water pipe between the pool and the heat pump must not exceed 10m.
Position the AQUALUX heat pump on the delivery side between the filter and the water treatment
system.
A by-pass system with three valves is used in order to adjust the flow rate of water from the pool passing
through the heat pump. In this way, the device can be removed without stopping the filtration.
Condensates must flow freely into the sewer.

ELECTRIC CONNECTIONS

Switch off the power supply before working on the pump and stop the hydraulic circuit
Electrical specifications
The protection must be ensured with a circuit breaker curve D.
Model
Differential protection
(mA) to install
Circuit breaker (A) to
install
2
Power cable (mm
)
2
Signal cable (mm
)
Conditions:
Maximum length of the power cable: 10 m.
If the power cable is ≥10m, the diameter must be increased.
The signal cable can be extended to 50m.
The heat pump must not operate if the filter is stopped. This function is performed by a
built-in flow switch. Check that the pump flow is sufficient for the switch to work.
NOTPACAQX - ind Q – 0413
machine.
Heat pump
Aqualux
Condensate drain
CAUTION: DANGER OF ELECTRIC SHOCK
104274
104275
30
10
3×2.5
3×2.5
3×0.5
3×0.5
104276
30
30
16
16
3×4
3×0.5
15/41
Automatic
treatment
to the return
inlets
104277
104278
30
30
20
10
3x6
5x2.5
3x0.5
3x0.5
104279
30
16
5x4
3x0.5