2.6

Generator operation

NOTICE
Only those generators must be used that have been designed for industrial
use on building sites. The operating instructions for the generator must be
observed!
The use of generators must comply with DVGW work sheet GW308, VDE 0100
Part 728, and the specifications and guidelines applying in the country of use.
NOTICE
The vaccum pumpe can be operated together with a FRIAMAT fusion unit at
the same generator. The manufacturer's instructions must be observed for the
common use with other electrical consumers!
2.7

Opening the device

WARNING
Electric shock from live parts! Danger of death!
• Never open the vacuum pump when it is supplied with operating voltage!
• The vacuum pump may be opened only by specialised personnel from an
authorised FRIATEC service station!
3.

Technical details

Technical details*
Order Ref.
Input voltage range
Frequency range
Ultimate vacuum
Protection Class
Operating temperature range
Dimensions (W x D x H)
Weight
*: Specifications subject to change.
18
Vacuum pump 230V
613827
230V
50/60Hz
approx. -900 mbar
IP 54
-10°C bis +45°C
approx. 345 x 215 x 315 mm
approx. 9,5 kg
Vacuum pump 110V
613828
110V
50/60Hz
approx. -900 mbar
IP 54
-10°C bis +45°C
approx. 345 x 215 x 315 mm
approx. 9,5 kg