Exemplary drawing.
Air supply requirements
Supply tool with a maximum pressure according to the technical data of this unit of clean,
dry air. Higher pressure drastically reduces tool life and/or can cause several injury.
Connect tool to air line using pipe, hose and fitting sizes shown in the diagram above.
Do not install a quick coupler directly into the air tool handle.
In order to have the tool working to full satisfaction the minimum air delivery must be at
least 10% higher than the indicated air consumption of the air tool.
Please consult the technical data in this instruction manual.
Instruction of use
Please make sure that if the tool is fitted with a torque/air regulator, that the torque
achieved complies with the application.
If an extra support handle is supplied with the tool, make sure that it will be fitted before
the tool is used and hold, if possible, the tool with two hands.
Lubrication
Use an air line lubricator with oil, adjusted to two (2) drops per minute. If an air line
lubricator cannot be used, then once a days 1 or 2 drops special (SAE10) air motor oil
needs to be added into the air inlet.