7) Procedure when changing
the configuration of the Wolf
heating system
8) Operation during failure of
the SmartHome central unit
Disabling access of the
SmartHome system to the
heating controls
Note 9
System and hydraulic
schemes
12
7) Changing the configuration
GB
8) SmartHome central unit failure
Whenever any changes are made in Wolf's heating system configuration
(e.g. adding a mixer circuit), both the ISM9 and the SmartHome system's
central unit must be restarted. Otherwise, the new components are not
recognised by the SmartHome system.
After the restart, the pairing process for the added modules must be carried
out according to the instructions of the SmartHome manufacturer.
In the event of a SmartHome central unit failure, Wolf's BM-2 system control-
ler takes over control of the heating system after 5 minutes. Manual interven-
tion in set value adjustment and program selection for the heating circuits /
heating circuits with mixer is now possible on the BM-2 again. The note
"Smart ISM" then disappears from the footer of the BM-2.
In the contractor level of the BM-2 (password: 1111, see BM-2 instructions)
the parameter "A26 SmartHome enabled" is available under "System". This
parameter can be used to manually deactivate and activate SmartHome
mode, and thus the influence of individual room temperature control on the
heating system. The parameter's factory setting is "ON".
The BM-2 ignores the SmartHome system's control commands whenever
the A26 parameter is on "OFF". This parameter can also be switched on or
off accordingly via the Wolf app and the portal (remote shutdown possible).
A17 P component
A18 I component
A23 Start time ALF
A26 SmartHome enabled
14:12
The Wolf website "www.wolf-heiztechnik.de." provides details of hydraulic
schemes that are suitable for combination with the SmartHome system.
Numbers for hydraulic schemes:
- 47-52-014-032
- 47-52-014-033
- 47-52-014-034
Contractor level, system
20K/K
10K/(K*h)
Smart ISM
18:00
ON
25/01/2016
3064779_201604