Step 3
As Coaxial cable has only two wires, we suggest you read the result of the LED scan using Manual mode.
3. Remote Test
Step 1
Plug one end of the tested cable to the transmitting RJ45 jack on the master unit marked with an arrow
and plug the other end into the remote terminator. If the tested cable is installed in a patch panel or wall
plate, you may use the included patch cable to solve the connector gender problem. Now, set the
Auto/Manual switch to Auto mode for one-person testing. Read the test results from the LED display on
remote terminator
4. Loop-Back-Test
Test a cable without remote unit:
(This test is usually only possible for non-installed cables.)
1. First Plug one end into the slot of the main unit is labeled TX (= transmitting) and the other end
into the slot with the RX (= receiving) labeled.
2. Second If at the same time on the bottom line of the display, the LEDs light up the top, then the
individual wires of the cable are wired correctly.
Test results
Continuity
Pin 2 is continued