Herunterladen Inhalt Inhalt Diese Seite drucken

Makita AC310H Betriebsanleitung Seite 2

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
ENGLISH
Explanation of general view
1. Air Tank pressure gauge
2. Regulated pressure gauge "HP"
3. Air regulator "HP"
4. Quick coupler "HP" (Air outlet)
5. Regulated Pressure gauge "RP"
6. Air regulator "RP"
7. Quick coupler "RP" (Air outlet)
8. Drain valve
9. Pressure Switch
SPECIFICATIONS
MAX Input Power
SCFM @ 40 PSIG (L/min @ 2.8 bar)
SCFM @ 90 PSIG (L/min @ 6.2 bar)
SCFM @ 300 PSIG (L/min @ 21 bar)
Cut-In Pressure
Cut-Out Pressure
Bore x Stroke x Qty
Voltage -Single Phase
Dimensions (L x H x W)
Outlet Max Pressure "HP"
(Exclusively for High Pressure Pneumatic Use)
Outlet Max Pressure "RP"
(Exclusively for Regular Pressure Pneumatic Use)
• Due to our continuing programme of research and development, the specifications herein are subject to change without
notice.
• Note: Specifications may differ from country to country.
IMPORTANT
Read the Safety Guidelines and ALL instructions carefully before operating.
2
Model
Hz
Motor RPM
Lubrication
Tank Size
Weight
Noise
9
7
6
3
AC310H
1800 W
3.7 (106 L)
3.6 (101 L)
2.7 (77 L)
2.3 MPa (23 bar)
2.8 MPa (28 bar)
62 mm x 31 mm x 1
45 mm x 10 mm x 1
220 - 240 V AC
1420 min
Oil-Less
1.6 gal (6.2 L)
36 kg (79.4 lb)
18-3/4" x 14-3/4" x 20" (476 x 375 x 507 mm)
2.6 MPa (26 bar)
0.9 MPa (9 bar)
L
WA
5
1
2
8
50 Hz
-1
90 dB
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis