Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Operation - Renkforce 1399993 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection
The MW connection (3) and the USW connection (4) may only be connected
to the corresponding antenna inputs of the appropriate receivers.
As a power source for the antenna may only be used a mains socket con-
nected to the public power network.
Be careful when handling the mains cables and mains connectors. The
mains voltage can cause fatal electric shocks.
Make sure that the voltage indicated on the antenna corresponds with the
mains voltage of your power supply. Never try to operate the antenna with
any other voltage.
When making the connections, make sure that the connecting cables can-
not be pinched or damaged by sharp edges.
The mains socket to which the antenna is connected must be near the
antenna and easily accessible, so that it can be quickly isolated from the
mains power supply in the event of any fault.
• Plug the connector of the USW connection (4) in the corresponding USW antenna
connector of your receiver (FM coaxial input 75 Ohm).
• Fasten the two cable lugs of the MW connection (3) on the medium wave antenna
connection (AM) of your receiver.
• Plug the mains plug into a mains socket.

Operation

• Switch on your receiver.
• Switch on the antenna by turning the rotary controller (2) clockwise. A clicking
sound is to be heard. The power indicator (1) will light up.
• Set the antenna's amplification in USW band as well, using the rotary controller (2).
Turn the rotary controller (2) clockwise until you can receive fine the selected USW
station on the radio set.
If the antenna's amplification is adjusted too high, this may cause a recep-
tion deterioration, because the reception device is then overmodulated. In
this case, decrease the amplification by turning the rotary controller (2) anti-
clockwise.
If you cannot achieve an optimum reception in spite of various amplification
settings, adjust the antenna's position and attempt in this manner to improve
the reception.
• To switch off the device, turn the rotary controller (2) anti-clockwise until you hear a
"click" sound. The operation indicator (1) goes off.
As the antenna has no amplification function in the medium wave band, it is
not necessary to turn it on for medium wave reception.
If you cannot achieve an optimum reception, adjust the antenna's position
and attempt in this manner to improve the reception.
Handling
• Never operate the antenna with damaged housing or missing covers.
• Never use the antenna immediately after it has been brought from a cold room into a
warm one. The condensation that forms might destroy the product. Allow it to reach
the room temperature. Wait until the condensation has evaporated.
• Never remove the mains plug from the mains socket by pulling on the cable; Always
unplug from the mains socket by means of the gripping area provided for this pur-
pose.
• Always disconnect the power plug from the mains socket, when the device is not in
use.
• For safety reasons always unplug the mains plug from the socket during a thunder-
storm.
Maintenance and care
Before cleaning the product, disconnect it from the power supply (unplug
the mains plug from the mains socket!).
Make sure that the inside of the device does not get wet or damp.
The antenna is maintenance-free; therefore, do never open the housing. If you do
open it, the warranty will be rendered null and void.
Inspect the device regularly for technical security, damage to the housing, the power
cable, etc. Should you find any damage, turn the device off and secure it against ac-
cidental use.
The outside of the housing should be cleaned only with a dry, soft cloth or brush.
Never use aggressive cleansing agents or chemical solutions, since they might dam-
age the surface of the housing.
Disposal
Electronic devices are recyclable waste materials and must not be disposed
of in the household waste!
Dispose of the product at the end of its service life in accordance with the
applicable regulatory requirements.

Technical data

Operating voltage............................... 230 V/50 Hz
Reception band .................................. 88 - 108 MHz USW
...............................................................
Amplification ....................................... 23 dB max. USW
Connection impedance ..................... 75 Ohm
Output level ......................................... 95 dBµV
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2016 by Conrad Electronic SE.
520 - 1600 kHz MW

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1399995

Inhaltsverzeichnis