stop the inflation immediately; the gas is filled with compressed air (it's strictly
forbidden to fill in pure oxygen or other gases harmful to human body). When
the air pressure in the cylinder reaches 3000psi /200bar/20MPa, stop the
inflation immediately to avoid any accidents.
⚫
Common Inflation Methods: electric pump inflation, manual pump inflation
and adapter inflation. When the aforesaid tools are used, please ensure that
the pressure can reach 3000psi/200bar/20MPa, otherwise the cylinder will
not be fully filled. When electric pump/manual pump is used for inflation,
oil-water separator shall be equipped.
The compressed air filled shall meet the requirements of human breathing to
⚫
ensure the air is pure and harmless to human body. If the pure compressed air
suitable for human body is not filled as required, the filter system or channel
in the cylinder valve may be blocked to cause malfunction.
3. Pressure Release
Press the release valve on the top of the cylinder valve to release the pressure.
If air leakage occurs after air filling, release the pressure in this way and check
the malfunction.
4. How to Use
Before use, please check any possible air leakage or water seeping into breathing
cavity of the cylinder valve. In case of air leakage, stop using it immediately.
In case of water seepage, please drain the water before use. The specific operation
is shown as follows:
⚫
Keep all the mouthpiece in mouth, bite the silicon part with teeth and shut the
mouth tightly. Press the silicone cap on the top of cylinder valve to discharge the
water in the breathing cavity by the released air, and then have normal breathing
with the mouth.
⚫
Check whether there are foreign objects (such as sand, etc.) in the breathing
cavity. If any, please clean up in time before use.
⚫
Use only after safety hazards have been eliminated. When in use, you can breathe
normally by biting the mouthpiece completely.
- 7 -