While installing the instrument take care of the arrow marking
on the body, determining the flow direction.
Ensure that all piping is absolutely clean and without any
damage. It is recommended to install an inlet filter in front of the
instrument and, when backflow could occur, also an outlet filter.
Piping with small diameter at higher flow rates has to be
avoided. The recommended length of the inlet pipe should be at
least 10 times the piping diameter.