3000126-RSHG-UK-DE
1.
UK – Product information
The exodraft Chimney Fan type RSHG is used as part of the fail-safe flue system for open flued gas
appliances, such as stoves and domestic boliers. The RSHG gives a horisontal discharge of the flue
gases. Max. 200 °C
Warning!
1.1
Construction and design
Construction
The body and casing are manufactured in cast aluminium, fitted with a stainless steel vane and
non-moving airpres-sure sensors linked to a pressure differential switch (PDS), ensuring correct
airflow when the fire is used. The chimney fan can be opened for service and cleaning purposes.
Main parts
The RSHG has the following main components
a
b
c
d
e
f
g
h
i
j
k
l
m
All installations must be carried out by competent personnel
inaccordance with national laws and regulations
Avoid chimney fires – ensure that the chimney has been swept
before mounting the fan.
The chimney fan must always be operating when the fireplace is
in use.
Please always read the installation instructions for the exodraft
control unit, before installation of the chimney fan.
Motor housing
Bottom section
Motor
Cooling plates
Vane
Safety hinge
Safety net
Armoured motor cable
Mineral wool mat
Safety wire with bolt and rawlplug
Location brackets, bolts and nuts
Pressure differential switch
Non-moving airpressure sensors
UK •
3