Peukert's exponent. The Peukert's exponent represents the effect of
F5.4
reducing battery capacity at higher discharge rates. When the Peukert
value of your battery is unknown, it is recommended to keep this value at
1.25. A value of 1.00 disables the Peukert compensation.
Default: 1.25
Range: 1.00 – 1.50
Self-discharge rate. This is the rate at which the battery loses capacity by
F5.5
itself, even when it is not used. The unit of this value is percent capacity
per month at the Nominal temperature (F5.2). The setting "OFF" disables
self-discharge compensation.
Default: 3.0%/month
Range: OFF / 0.1 –
25.0%/month
Charge Efficiency Factor (CEF). CEF is the ratio between the energy
F5.6
removed from a battery during discharge and the energy used during
charging to restore the original capacity. It is recommended to keep keep
this value at "AU" (automatic calculation). The setting "100" disables
charge efficiency compensation.
Default: AU
Range: 50 – 100% / AU Step size: 1%
F6:
Battery Monitor Properties
Firmware version. Displays the firmware version of the battery monitor
F6.0
(read only).
Default: x.xx
Shunt Amp Rating. This Function is linked to F6.2 and represents the Amp
F6.1
rating of your shunt at the given voltage indicated by F6.2. Included with
your battery monitor is a 500Amp/50mV shunt, meaning that at 500A
flowing through the shunt, a voltage of 50mV is generated across the small
'Kelvin' screw terminals of the shunt. This voltage will be used by the
battery monitor to measure the amount of current.
Default: 500A
Range: 10 – 9000A
Shunt milliVolt Rating. This Function represents the milliVolt rating of
F6.2
your shunt at the given current indicated by F6.1. The battery monitor
supports 50mV and 60mV shunts.
Default: 50mV
Range: 50/60mV
Backlight mode. Represents the duration of backlight activation in seconds
F6.3
after key-press. The backlight can also be set to be always "ON" or always
"OFF". Function setting "AU", activates the backlight automatically when
charge / discharge current exceeds 1Amp or when a key is pressed.
Default: 30sec
Range: OFF / 5 – 300 /
ON / AU
Alarm contact polarity. Enables selection between a normally open (NO)
F6.4
or normally closed (NC) contact.
Default: NO
Range: NO/NC
Voltage prescaler. This Function is only important when an optional
F6.5
voltage prescaler is installed on the battery monitor. All voltage related
Functions are linked to this Function F6.5. Always keep this Function set
to "1-1" when no prescaler is installed!
Default: 1–1
Range: 1-1 / 1-5 / 1-10
Temperature unit selection. Enables selection between degrees Celsius
F6.6
(°C) and degrees Fahrenheit (°F) in the temperature readout.
Default: °C
Range: °C/°F
Auxiliary input mode. This Function is used to configure the VA input
F6.7
terminal on the rearside of the battery monitor, and can be set in two
modes. In mode "0", the VA input operates in normal voltage
measurement mode. In mode "1", the VA input can be used to control the
backlight. In this mode, the backlight is switched ON at an input voltage
higher than 2V and switched OFF again if the voltage is below 1V.
Default: 0
Range: 0/1
Communication mode. This Function is used to configure the data output
F6.8
mode. There are four data output modes :
Mode "0": LinkPRO (broadcasting)
Mode "1": LinkPRO (request mode)
Mode "2": XBM compatibility mode (broadcasting)
Mode "3": XBM compatibility mode (request only)
Default: 0
Range: 0/1/2/3
Setup lock. When set to "ON", all functions (except this one) are locked
F6.9
and cannot be altered. The Reset menu is also locked.
Default: OFF
Range: OFF/ON
This pdf was downloaded from
Step size: 0.01
Step size: 0.1%/month
Step size: variable
Step size: variable
MarineSupplyDock.com

Reset menu

In the Reset menu, you can reset a number of items of your battery monitor This
menu can be accessed by the following sequence :
When the Reset menu is entered, you can use the < and > keys to browse through
the different reset items. By pressing the MENU key, the selected reset item can
be viewed. The default value for all reset items is "OFF". To actually reset the
selected item, use the < and > keys to change the value from "OFF" to "ON".
Pressing the MENU key again, will step back to the Reset menu. All reset items
set to "ON" will only be reset once the Normal Operating Mode is accessed again
by pressing the MENU key for 3 seconds. The following Reset menu items are
available :
Reset alarms. Use this reset item to reset or ignore all current alarms.
rSt.a
Reset Battery status. Use this reset item to reset your current battery
rSt.b
status (CEF, State-of-charge and battery history). You can use this reset
item after you have installed a fresh battery of the same specifications
as the previous one.
Reset Functions. This reset item can be used to reset all Function values
rSt.F
to factory default values.
Troubleshooting guideline
Problem
Remedy or suggestion
The monitor doesn't
• Check monitor and battery side connections.
operate (no display)
• Make sure the inline fuses are installed and not
blown.
• Check battery voltage. Battery might be flat. Vbatt
must be >8VDC.
• Try to restart the monitor by removing / placing the
fuses again.
Current readout gives
• Current sense leads from the shunt are reversed.
wrong polarity (positive
Check the installation guide.
current instead of
negative when
discharging)
The monitor resets all the
• Check the wiring for corrosion and / or loose
time
contacts.
• Battery might be flat or defective.
No changes can be made
• Check if the setup-lock is OFF (Function F6.9)
in the Function setup
• Your LinkPRO might be locked by the superlock.
Ask the installer for the password to unlock the
monitor using the LinkPRO Communicatoion Kit.
"CHARGE" or
• Charge battery full (synchronize your battery with
"SYNCHRONIZE"
the monitor)
keeps on flashing
• Check the Auto-sync parameters in Functions F1.0,
F1.1 and F1.2 for possible wrong settings.
State-of-charge and/or
• Check if all current is flowing through the shunt
time-to-go readout not
(the negative terminal of the battery may only
accurate
contain the wire going to the battery-side of the
shunt!).
• Current sense leads from the shunt are reversed.
• Check all Battery properties Functions (F5)
• Check if battery monitor is synchronized.
Display returns '- - - -' in
• Connection with temperature sensor is lost. Check
temperature readout
for failed connections and/or cable damage.
Battery voltage readout is
• Check prescaler setting in Function F6.5
highly inaccurate