Owner's Guide
Thank you for purchasing the LinkPRO high precision battery monitor.
Important Safety Information
Misusing or incorrectly connecting the LinkPRO may damage the equipment or
create hazardous conditions for users. Read and keep this Owner's Guide and the
enclosed Installation Guide.
WARNING: Fire hazard
Do not operate this equipment unless it has been installed by a qualified
installer in accordance with the Installation Guide.
WARNING
Do not use LinkPRO in connection with life support systems, medical
equipment, or where human life or medical property may be at stake.
FCC Information
This Class B digital apparatus complies with Canadian ICES-003 and Part 15 of
the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
NOTE: The Class B limits are designed to provide reasonable protection against
harmful interference in a residential installation.This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur
in a particular installation.If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
LinkPRO Display and Control Overview
1. Charge battery indicator
2. Numeric value indicator field
3. Setup lock / Master lock indicator
4. Main battery or Auxiliary battery indicator 10. Next value or Right key (>)
5. State-of-charge bar
6. Charging in progress indicator
Synchronisation
In order to keep your LinkPRO battery monitor delivering accurate status
information about your battery, it is important to regularly synchronize your
battery monitor with your battery. As explained in the quick start guide, a
synchronisation step is also needed before you can actually use your battery
monitor. During operation, the battery monitor automatically indicates when a
synchronisation is required, by displaying the message SYNCHRONIZE.
A synchronisation step means nothing more than performing a complete charge
cycle on your battery. A charge cycle will be considered complete when both
Auto-sync parameters F1.0, F1.1 and F1.2 (see Function setup menu) are met.
This typically means : when the battery charger switches to float mode. By
meeting these conditions, the battery is considered full, which will be indicated
by a flashing FULL message on the display. Besides this, the State-of-charge
readout will be set to 100% and the Amphour readout reset to 0Ah. The FULL
message will disappear when a key is pressed, or automatically, when the battery
starts discharging again.
This pdf was downloaded from
Xantrex and Smart Choice For Power are trademarks of Xantrex International, registered in the U.S. and other countries. Other trademarks, registered trademarks, and product names are the property of th
Unless specifically agreed to in writing, Xantrex Technology Inc. ("Xantrex"): (a) makes no warranty as to the accuracy, sufficiency or suitability of any technical or other information provided in its manu
such information. The use of any such information will be entirely at the user's risk; and (c) reminds you that if this manual is in any language other than English, although steps have been taken to mainta
7. Alarm activated indicator
8. Readout units
9. Synchronize indicator
11. Menu key
12. Previous value or Left key (<)
MarineSupplyDock.com
Performing synchronisations regularly is also important to keep your battery
healthy and to increase it's lifetime. You will notice that if you are often
performing full charge cycles yourselves, the battery monitor will most likely not
display the SYNCHRONIZE message, since the battery is already kept in good
sync with the battery monitor.
Besides automatic synchronisations based on meeting the Auto-Sync Functions,
you can also manually synchronize the battery monitor with your battery when
you are sure your battery is fully charged. This can be accomplished by pressing
both < and > keys simultaneously for three seconds. After these three seconds,
the flashing FULL message appears on the the display just like when it is
automatically synchronized.
Status menu
The Status menu is a read only menu that shows the battery monitor's current
status of several items. This menu can be accessed by the following sequence :
When the Status menu is entered, you can use the < and > keys to browse through
the different status itmes. By pressing the MENU key, the selected status item can
be viewed. Pressing the MENU key again, will then step back to the Status menu.
From any menu position, the Normal Operating Mode can be accessed again by
pressing the MENU key for 3 seconds. The following Status menu items are
available :
Alarm Status. When multiple alarms are activated, use the < or > keys to
St.1
browse through the currently active alarms. When no alarms are activated,
this item displays "----".
Days running. The number of days the battery monitor is operating to
St.2
monitor your battery. This item resets when a battery reset is executed (see
Reset menu).
Days since last synchronized. The number of days the battery monitor has
St.3
not been synchronized. This item resets when the battery monitor is
synchronized or when a battery reset is executed (see Reset menu).
Charge Efficiency Factor (CEF). The charge efficiency factor used by the
St.4
battery monitor. Depending on the value set in Function F5.6, this item
displays the automatically calculated CEF or the manually set CEF
History menu
The History menu is a read only menu that shows the battery monitor's History
data. History data are special events that are stored in internal memory. This
menu can be accessed by the following sequence :
When the History menu is entered, you can use the < and > keys to browse
through the different History items. By pressing the MENU key, the selected
History item can be viewed. Pressing the MENU key again, will then step back to
the History menu. From any menu position, the Normal Operating Mode can be
accessed again by pressing the MENU key for 3 seconds. The following History
menu items are available :
H1: Battery History
Average discharge in Ah. This number will be recalculated after each
H1.0
synchronization.
Average discharge in %. This number will be recalculated after each
H1.1
synchronization.
Deepest discharge in Ah.
H1.2
Deepest discharge in %.
H1.3
Total Amphours removed. The total number of Amphours removed from
H1.4
the battery. When exceeding 10000Ah, the units are kAh and the value
displayed must be multiplied by 1000.
Total Amphours charged. The total number of Amphours charged to the
H1.5
battery. These Amphours are not compensated by the Charge Efficiency
Factor (CEF). When exceeding 10000Ah, the units are kAh and the value
displayed must be multiplied by 1000.
Number of cycles.
H1.6
Number of synchronizations. This is the number of times the battery is
H1.7
fully charged meeting the Auto-sync Functions.
Number of full discharges. The number of times the battery has been fully
H1.8
discharged reaching a State-of-charge of 0.0%.
H2: Alarm History
Number of Low Battery alarms.
H2.0
Number of Main battery low voltage alarms.
H2.1
Number of Auxiliary battery low voltage alarms.
H2.2
Number of Main battery high voltage alarms.
H2.3
Number of Auxiliary battery high voltage alarms.
H2.4

Werbung

loading

Inhaltszusammenfassung für Xantrex LinkPRO

  • Seite 1 Xantrex and Smart Choice For Power are trademarks of Xantrex International, registered in the U.S. and other countries. Other trademarks, registered trademarks, and product names are the property of th Unless specifically agreed to in writing, Xantrex Technology Inc. (“Xantrex”): (a) makes no warranty as to the accuracy, sufficiency or suitability of any technical or other information provided in its manu...
  • Seite 2: Reset Menu

    • Check if the setup-lock is OFF (Function F6.9) Voltage prescaler. This Function is only important when an optional in the Function setup • Your LinkPRO might be locked by the superlock. F6.5 voltage prescaler is installed on the battery monitor. All voltage related Ask the installer for the password to unlock the Functions are linked to this Function F6.5.
  • Seite 3: Wichtige Sicherheitshinweise

    H2.4 Xantrex and Smart Choice For Power ist eine Marke von Xantrex International.. Andere Marken, eingetragene Marken und Produktbezeichnungen sind Eigentum der jeweiligen Eigentümer und werden i WENN NICHT AUSDRÜCKLICH SCHRIFTLICH FESTGELEGT, TRIFFT FOLGENDES AUF XANTREX TECHNOLOGY INC. (IM FOLGENDEN KURZ "XANTREX" GENANNT) ZU. XANTR This pdf was downloaded from MarineSupplyDock.com...
  • Seite 4: Fehlersuche

    Bereich : NO/NC Einrichter nach dem Paßwort, damit Sie den Spannungsvorteiler. Diese Funktion ist nur dann relevant, wenn ein F6.5 Monitor mit Hilfe der LinkPRO optionaler Spannungsvorteiler am Batteriemonitor angeschlossen wurde. Kommunikationsschnittstellenkit . Alle spannungsbedingten Funktionen stehen in Verbindung mit der Funktion F6.5.
  • Seite 5 MarineSupplyDock.com (« Xantrex ») (a) ne garantit pas que les informations techniques ou autres fournies dans ses manuels ou autre documentation sont exactes, exhaustives ou appropriées; (b)ne saurait être tenu responsable de (« Xantrex ») (a) ne garantit pas que les informations techniques ou autres fournies dans ses manuels ou autre documentation sont exactes, exhaustives ou appropriées; (b)ne saurait être tenu responsable de de toute information se fait aux risques et périls de l'utilisateur;...
  • Seite 6: Menu Réinitialisation

    OFF (Fonction F6.9) Par Défaut : NO Plage : NO/NC paramétrage • Votre LinkPRO est peut-être verrouillé par le Super- lock. Demandez le mot de passe à votre installateur Indexeur de Tension. Cette Fonction n'est important que lorsqu'un F6.5 indexeur de tension optionnel est installé sur le contrôleur de batterie.

Diese Anleitung auch für:

84-2031-00