Area of use
The door alarm is designed to monitor closed doors and emits an acoustic signal when the door is opened. It is
installed inside the house and is suitable for doors opening to the right or the left.
The door alarm is switched on and off with a key. 2 different operating modes can be selected with a function
switch:
-
When you are at home select the "Immediate alarm" mode.
- When you are leaving select the "Delayed alarm". This allows you enough time to leave or enter your home
without triggering the alarm. The alarm emits a loud signal.
Pack contents
We supply the door alarm with the following components (see Fig. A)
1 x Door alarm
3 x Adhesive tape
1 x Magnet
4 x Fixing screws
2 x Switching keys
1 x Operating instructions
Description
On the front of the casing (see Fig. A)
[1] Door alarm
[
7]
Fastening screw for the
[2] Key switch
battery compartment cover
[3] Function switch
[
8]
Marking showing left
[4] Key
hand magnetic switch
[5] Marking showing right-
[9]
Magnet
hand magnetic switch
[
10] Light-emitting diode (LED)
[6] Battery compartment cover
On the rear of the casing (see Fig. B)
[11] Upper mounting surface
[
13] Upper screw mounting
[12] Lower mounting surface
[
14] Lower screw mounting
On the rear of the magnet casing (see Fig. B)
[15] Base plate
[
17] Screw mounting
[16] Screw mounting
Fastening material
[18] Adhesive pad 3x
[
20] Adhesive pad 1x
[19] Fixing screws 4x
Technical data
Operating voltage:
3 V
DC
Current consumption:
max. 200 mA
Power supply:
2 x batteries of type LR03 – 1.5 V (AAA)
Sensors:
2 x magnetic switches in the side areas of the device casing
Switching distance max.:
approx.10 mm
Alarm signal sound level:
90 dB (± 5 dB) at 1 m distance
Alarm duration:
max. 90 sec
Operating modes:
immediate alarm
delayed alarm
Casing material:
ABS plastic
Dimensions of door alarm casing:
54 x 104 x 26 mm (wxhxd)
Dimensions of magnet casing:
12 x 40 x 13 mm (wxhxd)
Weight:
99 g Door alarm with accessories (batteries not included)
Safety instructions
The following instructions are for your own safety and satisfaction when operating the device. Please note that
non-compliance with these safety instructions can lead to a serious risk of accident.
Explanation of the symbols and terms used:
Danger
: failure to observe this instruction endangers life and health.
Caution
: failure to observe this instruction poses a risk to property.
Tip
: following this advice will help you to achieve optimal results.
Danger
!
Do not leave small children unsupervised with the packaging material. Danger of suffocation.
!
Keep children away from the device. The alarm signal is loud.Danger to life and risk of injury.
!
Do not leave children unsupervised with the device. Danger to life and risk of injury.
!
Do not use the device in the presence of sick or disabled people and animals. Shock caused by the alarm
signal can endanger life and poses a risk of injury.
!
Do not damage any gas, electricity or telecommunication lines when fitting the device. Danger to life and risk
of injury and damage.
!
Do not allow leaky or damaged batteries to come into contact with the skin or eyes. Use suitable protective
gloves and clothing. Danger to life and risk of injury from corrosive acid.
!
Never expose the device to fire, heat or to temperatures of over 50° C for any length of time. Danger to life
from explosion.
!
Do not short-circuit the batteries or recharge them. Danger to life from explosion.
!
Make sure that your hearing is not exposed to the loud alarm signal for any length of time. This can cause
serious damage to the hearing.
!
Make sure that the alarm signal is not triggered close to the ears. This can cause serious damage to the
hearing.
Caution
!
Use the device only with batteries of type LR03 1.5 V (AAA).
!
Make sure that you insert the batteries with the correct polarity.
!
Remove the batteries from the device during long periods of non-use.
!
Only use new batteries and under no circumstances used batteries. Make sure that both batteries are charged
to the same level.
!
Make sure that the device does not come into contact with moisture.
!
Protect the device from strong magnetic or electric fields.
!
Protect the device from strong mechanical strain and shocks.
!
Only use the device with the supplied original parts.
!
Check before initial operation that all components are assembled in accordance with the operating
instructions.
!
Before assembly and initial operation of the device, check that the delivery is complete and undamaged.
!
Take care not to damage glass or mirrored surfaces on the door leaf when fixing the device in place.
!
The device must only be repaired by authorized and skilled specialists. Failure to observe this instruction
poses a risk of damage resulting from improper use and a loss of the warranty.

Initial operation

Inserting the batteries
Caution
: use new batteries only and under no circumstances used batteries. Make sure that both batteries
are charged to the same level.
Tip
: you will need a crosstip screwdriver for inserting/removing screws and a slotted screwdriver for levering
work.
#
Before inserting the batteries make sure that the alarm function is deactivated.
#
Insert the key [4] into the key switch [2] and turn it to OFF position.
#
Pull the key out of the key switch. The arrow marking points to the OFF position. The door alarm is switched
off.
#
Release the fastening screw [7] on the battery compartment cover [6] in anticlockwise direction (see Fig. C).
#
Pull the battery compartment cover down and remove it from the door alarm.
#
Insert two new batteries of type LR03 1.5 V (AAA) in the battery compartment.
#
Make sure that the batteries are inserted with the correct polarity.
Activating / deactivating alarm functions
You can set two different alarm functions on the door alarm:
Immediate alarm
and delayed alarm
.
The magnetic sensors of the activated door alarm react as soon as the distance to the magnet becomes greater
than approx. 10 mm. When the alarm responds, the loud alarm signal is emitted for approx. 90 sec. After the
alarm has been triggered, the LED [10] lights up green. As soon as the door is closed completely again, the alarm